744 Documenting Process Calibrator Users Manual

2022-05-10
●The Fluke 744 Documenting Process Calibrator(hereafter referred to as the calibrator) is a battery-powered, hand-held instrument that measures and sources electrical and physical parameters, and provides basic HART communicator functions when used with HART-capable transmitters. Refer to the 744 HART Mode Users Guide for instructions on how to use the HART communication feature.
●The calibrator lets you troubleshoot, calibrate, verify,and document your work on process instruments.Calibrator Specifications are at the back of the manual.
●A summary of the measuring and sourcing functions provided by the calibrator is shown in Table 1. In addition to these functions, the calibrator has the following features:
●General features:
■An analog display to make it easy to read measurements when the input is unstable.
■A setup option that lets you set the display to English, French, German, Italian, or Spanish.
■A thermocouple (TC) input/output jack and internal isothermal block with automatic reference-junction temperature compensation.Or, you can manually enter an external temperature reference.The ability to store results for later review.
■The ability to automatically log up to 8,000 data points.
■A serial computer interface for uploading/downloading tasks, lists, and results.
■Automatic calibration procedures for transmitters and limit switches using split screen MEASURE/SOURCE mode.
■Transmitter mode in which the calibrator can be configured to emulate the functions of a process instrument.
■Built-in calculator with square-root function, and accessible registers containing measure and source values.
■An optional bar code wand for entering alphanumeric characters.
●Measuring features:
■Damping (smoothing of the last several readings), with display indicator of damped status.
■Display of measurements in engineering units,percent of scale, square-law inputs, or custom units.
■The ability to capture and display minimum and maximum measured levels.
●Sourcing features:
■The ability to set source values to engineering units, percent of scale, square-law outputs, or custom units.
■Manual and automatic stepping, and an output ramp feature for testing limit switches. Trip detect is either a 1 V change or a continuity status change (Open or Short) from one ramp increment to the next.

FLUKE

744Fluke 744TL24AC20TP20HARTBP7235BC7217Fluke-700SWFluke-700BCWFluke-700-IVFluke-700P01Fluke-700P02Fluke-700P03Fluke-700P22Fluke-700P23Fluke-700P04Fluke-700P24Fluke-700P05Fluke-700P07Fluke-700P06Fluke-700P08Fluke-700P09Fluke-700P29Fluke-700P30Fluke-700P31Fluke-700PA3Fluke-700PA4Fluke-700PA5Fluke-700PA6Fluke-700PV3Fluke-700PV4Fluke-700PD2Fluke-700PD3Fluke-700PD4Fluke-700PD5Fluke-700PD6Fluke-700PD7Fluke-700PCK700PTP700HTPFluke-700TC1 TCFluke-700TC2 TCC781C789BE9005BE9005 SeriesBP721774X Series74XTL seriesAC seriesTP series80T-IR80T-150U80PK series80PK80i-41080i-101080i-500s80i-1000s80i-kW

More

Part#

Documenting Process Calibrator

More

More

User's Guide

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

2/99

Ren.1

691287

1.9 MB

- The full preview is over. If you want to read the whole 138 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: