Micron Optics, Inc. os3100 Strain Gage(Weldable) Installation Procedure

2022-05-07
■Introduction
●Spot welding is the preferred method of mounting an os3100 gage to steel.A portable capacitive-discharge spot welder having 50 watt-seconds minimum energy rating is recommended for best results.The spot welder should be equipped with a small welding electrode having a spherical tip measuring approximately .030 inches [.76 mm] in diameter.It is often helpful to practice weld technique using a blank os3100 gage. Best results are usually obtained with a setting of 50 watt-seconds and firm pressure on the electrode. After making a practice weld, pull the gage off of the surface. A properly formed weld will result in a small piece of the surface or gage to break away. If needed, adjust the weld energy and electrode pressure until a satisfactory weld is obtained.(Contact Micron Optics for Welder recommendation).