METRACELL BT PRO Portable Battery Tester Condensed Operating Instructions

2022-04-26
●Safety Instructions:
■Observe this documentation, in particular all included safety information, in order to protect yourself and others from injury, and to prevent damage to the instrument.
▲Carefully and completely read and adhere to these condensed operating instructions, as well as the instrument’s operating instructions.
▲Use only the specified accessories with the instrument.
▲Carefully and completely read and adhere to the product documentation for optional accessories. Retain these documents for future reference.
▲Tests may only be performed by a qualified electrician, or under the supervision and direction of a qualified electrician. The user must be instructed by a qualified electrician concerning performance and evaluation of the test.
▲Wear suitable and appropriate personal protective equipment (PPE) whenever working with the instrument.
▲Implement adequate measures for protection against electrostatic discharge (ESD).
▲Observe and comply with all applicable DIN, VDE, EN, IEC and ANSI guidelines. Inform yourself concerning the operating company’s specifications and guidelines, as well as those of the respective battery manufacturers.
▲Batteries are electrochemical components with very high short-circuit currents. Avoid short-circuits which endanger yourself as a user, the entire system or operating person-nel.
▲If the instrument doesn’t function flawlessly, remove it from operation and secure it against inadvertent use.
▲The instrument may only be used as long as it’s in good working order. Inspect the housing before use. Pay particular attention to any possible cracks and the insulation around the sockets. Damaged components must be replaced immediately.
▲Accessories and cables may only be used as long as they’re fully intact. Inspect all cables and accessories before use. Pay particular attention to damaged hous-ings, broken insulation or kinked cables.Damaged components must be replaced immediately.
▲Do not use the instrument after long periods of storage under unfavorable conditions (e.g. humidity, dust or extreme temperature).
▲ Do not use the instrument after extraordinary stressing due to transport.
▲Do not use the instrument in potentially explosive atmospheres.
▲Use the instrument only within the specified ambient conditions.
▲Use the instrument only in accordance with the specified protection class (IP code).
▲The instrument must not be exposed to direct sunlight.
▲The instrument and the included accessories may only be used for the measurements described in this manualand in the operating instructions of the instrument.
▲Only use the accessories and the charger which are included with the battery tester or listed as optional accessories.
▲Only use the instrument as well as the accessories within the specified measuring cate-gory.
▲The measurement cables and all external cabling must not exceed an overall length of 1 meter.
▲Plugging in the measurement cables and the power pack must not necessitate any undue force.
▲Connect the ground wire before connecting the voltage conducting cable, and discon-nect the voltage conducting cable before disconnecting the ground wire.
▲Check measurement cable continuity.
▲Avoid short circuits due to incorrectly connected measurement cables.
▲Never touch the conductive ends of the alligator clips, the test probes, the Kelvin probes and the angle probes.
▲Make sure that the alligator clips, test probes, Kelvin probes and angle probes make good contact.
▲Do not move or remove the Kelvin probes and/or angle probes during a measurement.Unwanted sparking may otherwise occur due to test current.
▲Do not remove or move the alligator clips, test probes, Kelvin probes or angle probes until measurement has been completed. This is indicated by means of an acoustic acknowledgment.
▲Avoid simultaneously contacting the battery and the frame or hardware, which may be grounded.
▲The battery tester is equipped with a transponder module. Determine whether or not use of the 125 kHz frequency is permissible in your country.
▲The battery tester is equipped with a Bluetooth® module. Determine whether or not use of the implemented range of frequencies from 2.402 to 2.480 GHz is permissible in your country.
▲The input at the P+ measurement jack is equipped with a fuse link. The instrument may only be used as long as this fuse is in flawless condition.A defective fuse may only be replaced by our repair service.
▲The instrument only works with inserted batteries.
▲The battery charger may only be connected to electrical systems (TN or TT) with a maxi-mum of 230/400 V which comply with applicable safety regulations (e.g. IEC 60346, VDE 0100) and are protected with a fuse or circuit breaker with a maximum rating of 16 A.
▲Do not use the instrument while the internal batteries are being charged.
▲Do not use the instrument if the battery compartment cover has been removed.Touch contact with dangerous voltage is otherwise possible.
▲Always create a backup copy of your measurement data.

Gossen Metrawatt

METRACELL BT PRO

More

Part#

Portable Battery Testermultifunctional instrument

More

testing batteries ]battery blocks ]

More

User's Guide

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

4/9.21

668 KB

- The full preview is over. If you want to read the whole 20 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: