26.55.710 26.55.720 300AMP. POWER RELAY 28VDC
■ MIH. INSOLATION RESISTANCE, INITIAL: 100 MEGOHMS
■ AFTER LIFE OR ENVIRONMENTAL: 50 MEGOHNS
■ DIELECTRIC WITHSTANDING VOLTAGE SEA- LEVEL 1 MINUTE: 1050 VOLTS
■ DIELECTRIC WITHSTANDING VOLTAGE ALTITUDE 1 MINUTE: 500 VOLTS
■ MAX. CONTACT DROP INITIAL: 0.15 VOLTS
■ AFTER LIFE TEST: 0.175 VOLTS
■ OVERLOAD: 2400 AMP FOR 10 SEC; 600 AMP FOR 40 SEC
■ RUPTURE CURRENT: 3000 AMP
■ DUTY RATING: 300 AMP CONTINUOUS
|
|