●Introduction
■The manual assumes that the user has technical knowledge of and experience with power supply systems, explosion protection, as well as planning and installing power systems. It does not provide an introduction to power systems or explosion protection for inexperienced users. The content of this manual applies in conjunction with the respective datasheets, Declaration of Conformity and Certificate of Compliance. For further information please refer to the Pepperl+Fuchs "Wiring and Installation Guide."Substantial amounts of voltage, current and power are provided by the supply. Read this manual carefully before installation and operation to avoid risk of damage, failures, or personal injury. Take great care on input and output supply lines to protect from the effects of short circuits and provide the required ground connections.
Subject to modifications
●Specifications
■PS3500 has a wall-mount, multi-slot backplane accepting hot swappable plug-in power converter modules that provides an isolated output at 24 V DC nominal.Each power module has an individually isolated input port accepting either AC or DC that provides inrush current limiting and power factor control. The output port is completely isolated from the input and provides up to 15 A per module at a nominal 24 V DC (adjustable 22.5 to 30 V from chassis mounted trimmer) with a load sharing configuration for paralleled output operation. Input and output lines can be wired independently or in parallel providing N+1 redundant structures.System configuration is obtained by wiring and configuration DIP switches on the various backplane slots leaving power modules interchangeable and easily swappable under load. All relevant failures in the modules are detected and signaled by individual LEDs and alarm relays providing a flexible combination of redundancy, fault tolerance, and automatic fault detection ideally suited to critical applications.Full compliance to the EU directives for EMC and low-voltage equipment ensure minimum emissions and high immunity in harsh environments. High conversion efficiency normally permits natural convection cooling operation eliminating cooling fans for most application requirements.

Pepperl+Fuchs

PS3500-PM-1.24.15PS3500-TB-3PS3500-TB-6PS3500 seriesPS3500PS3500-TB-*PS3500-PMPS3500-TBPS3500-DM

More

Part#

REDUNDANT POWER SUPPLY

More

More

User's Guide

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

01/22

DOC T-B001HENG

2.8 MB

- The full preview is over. If you want to read the whole 26 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: