ICP DAS Release Stable and Cost-effective Data Acquisition Auto-Report System?

2022-01-19
● Introduction:
■ Please refer to Section 2 and 3 for VC++ 6.0 demo program.
■ Please refer to Section 2 and 4 for VB 6.0 demo program.
■ Please refer to Section 6 for more information about Ethernet security.
■ Many applications need to monitor/collect large amount of I/O and acquisition data distributed in wide-spread location for safety and management. The usual way to implement this is to apply one or couples of central PC/Server to poll (request one by one in turn) every PAC/PLC periodically in every spread location. This generates three disadvantages.
◆The CPU loading of the central PC/Server will become too heavy. That is because it must request every distributed local PAC one by one in turn periodically. So the result is the PC/Server becoming un-effective.
◆The second one is when the amount of local PACs is a little more or large, the PC/Server can not handle emergency events (because it request PAC in turn).
◆Every local PAC should setup a fixed Internet IP address for the PC/Server to request them. This waste money and Internet resource a lot.
■ICP DAS ISaGRAF PACs I-7188EG, I-8437-80, and I-8837-80 support Auto-report data acquisition and I/O data to the remote Internet PC/Sever via UDP/IP protocol. They can be setup to report periodically and report at any time when emergency event happens. Moreover, at any time, the PC/Server can send command to the local PAC if necessary. For example, the time synchronization. This feature is very useful in the below three applications.
■ Useful Applications:
◆ Distributed energy monitoring/management system, like electric power, gas, oil, water dam, etc.
◆ Distributed facility safety monitoring/management system, like elevator, building, stock room, etc.
◆ Other possible distributed data acquisition system.

ICP DAS

I-7188EGI-8437-80I-8837-80

More

Part#

ISaGRAF PACs

More

energy monitoring ]energy management system ]electric power ]gas ]oil ]water dam ]facility safety monitoring ]facility safety management system ]elevator ]building ]stock room ]

More

FAQ

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

Jun.2007

Version 1.0.0

FAQ-065

539 KB

- The full preview is over. If you want to read the whole 20 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: