●The flow sensor functions according to the calorimetric princi-ple. The measuring probe is heated by a few degrees (Celsius) above the temperature of the medium.
●Heat is dissipated by the medium flowing past. The difference in temperature between the medium and the sensor is a mea-sure for the flow condition which occurs.
●A corresponding switching signal can be assigned for a speci-fic flow condition using the potentiometer of the integrated amplifier electronics.
●In addition, a switch-on delay becomes active for 20 to 40s. This delay depends on the set response sensitivity and ensures that, for example, no fault message is issued when a fan starts up.
●When installing, it is essential to ensure that the sensor head is fully surrounded by the medium to be monitored, not only when the medium is at rest but also when it is flowing.
●setting instructions:
■After presetting the nominal flow, turn the potentiometer to the left limit stop. The LED must light up for at least 5 seconds. After approx. 20 seconds, turn the potentiometer clockwise gradually until the LED just extinguishes. The correct switching point setting is achieved by now turning the potentiometer back counterclockwise by 1 to 1.5 turns.

IPF ELECTRONIC

SL180100SL200100SL220100AS000006

More

Part#

FLOW SENSORS

More

More

Datasheet

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

2020/4/8

1.2 MB

- The full preview is over. If you want to read the whole 4 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: