OTDR: Two-Way Optical Fiber Measurement
● When light is injected into an optical fiber, some of it is scattered within the optical fiber to the opposite end of the light's path. This is called backscattered light. Each optical fiber has its own backscattered light value, or level. Since the connection loss for fibers with different backscatter levels varies according to the measurement direction, correct loss assessment requires measurement from both ends.
● For example, a fiber whose backscatter level is -60 dB is connected to a fiber of -55 dB at a loss of 3 dB:
▲ When an Optical Time Domain Reflectometer (OTDR) measures from End A, the light travels at a backscatter level of -60 dB and then declines by 3 dB at the connection point. However, since the backscatter level beyond the connection point is -55 dB, which is higher than the A side by 5 dB, the backscatter level is displayed as 2 dB due to the difference between the connection loss and the backscatter level of the B side. The loss of event 1 is -2 dB, which looks like the light is amplified. This type of event is also referred to as a "gainer".
▲ On the other hand, when the OTDR measures from End B, the light travels at a backscatter level of -55 dB and declines by 3 dB at the connection point. However, since the backscatter level beyond the connection point is -60 dB, the light declines by an additional 5 dB. It therefore declines 8 dB in total. The loss of event 1 is displayed, in fact, as 8 dB. Conversely this type of event is also referred to be a "loser"
|
|
Application note & Design Guide |
|
|
|
Please see the document for details |
|
|
|
|
|
|
|
English Chinese Chinese and English Japanese |
|
2020/10/19 |
|
R0 |
|
KSR-0978-AF075 |
|
269 KB |
- +1 Like
- Add to Favorites
Recommend
All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.