●General installation information
■The following installation information should be taken into account in the design and assembly of cam roller linear guide rail systems. This will ensure smooth, quiet and low-wear running and proper function over prolonged use.
■The mounting surfaces of cam roller linear guide rail systems (guide rails and cam roller carriages) must be level, parallel and at right angles as well as correctly aligned to each other. If end stops are used, they must be positioned such that they are reached as simultaneously as possible.
■Mounting holes should be applied in such a way that twisting or warping of the guide rails during installation is excluded. The specified mounting tolerance of +0.2 / +0.5 mm results in tensile loading of the rail in the direction of the application center, which ensures optimal and low-wear running.
■After the cam roller linear guide rail systems are mounted, they must be checked to ensure smooth running. In case of discrepancies, such as sticking or warping, the cause has to be determined and eliminated through appropriate actions