Connecting Multiple MSC8102 Devices on a System Bus

2021-10-26
●This application note describes how to connect up to eight MSC8102 devices in a system, each configured differently. No additional glue logic is needed for reset configuration. In a typical multi-MSC8102 system, one MSC8102 device acts as the configuration master and all other MSC8102 devices act as configuration slaves. The configuration master reads the various configuration words from EPROM and uses them to configure itself as well as the configuration slaves.
●To configure a multiple-MSC8102 system, you must complete the following tasks:
■Connect the CNFGS, RSTCONF, and HRESET signals properly.
■Connect the 60x-compatible data bus between all MSC8102 devices.
■Configure the Hard Reset Configuration Word (HRCW) for all MSC8102 devices at the correct addresses.

NXP

MSC8102

More

Part#

More

More

Application note & Design Guide

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

2/2003

Rev. 0