Mounting instruction for Reed Relay MRX series

2021-10-21
●Those Reed Relays serve as galvanic isolation of intrinsically safe circuits and not intrinsically safe circuits within operating devices which are installed outside an explosive area.
●The coil or the contacts can be connected with the intrinsically safe circuit. The circuits controlled by these contacts can only be of 1 type – i.e. intrinsically safe or not intrinsically safe. Mixing of circuits is not permitted. Connection of more intrinsically safe circuits, by means of the relay contacts, is permitted only when the intrinsic safety is not lost in the process.