Signal Analyzer MS2830A Microwave Product Brochure
2021-10-14
●The Signal Analyzer MS2830A-044/045 includes a spectrum analyzer function with upper frequency limits of 26.5 GHz and 43 GHz.Combining it with the High Performance Waveguide Mixer or the External Mixer MA2740C/MA2750C series supports measurements up to 325 GHz. It supports measurements of Tx characteristics, including adjacent channel leakage power, spectrum mask, and frequency counter, as well as spurious measurements requiring a wide dynamic range.
●Installing the bandwidth analysis option up to 125 MHz adds signal analyzer functions for checking phenomena that are hard to check using a spectrum analyzer, such as frequency vs. time, phase vs. time, spectrogram, and CCDF. In addition, optional measurement software supports modulation analysis. Moreover, installing a preselector bypass option enables use of the signal analyzer and modulation analysis functions up to 26.5 GHz/43 GHz (MS2830A-044/045). Finally, it can be customized to support a range of application-specific measurements.
◆Installing a microwave-band preamp supports measurement of weaker signals.
◆Using the 1st local signal output as an external mixer supports measurement of high-frequency signals up to 325 GHz.
◆Using the 1st IF signal output as a down converter supports analysis in combination with external equipment
■Key Features:
●Basic Performance/Functions
◆Frequency Range
▲MS2830A-044: 9 kHz to 26.5 GHz
▲MS2830A-045: 9 kHz to 43 GHz
◆Measures up to 325 GHz using High Performance Waveguide Mixer and External Mixer
▲Frequency Range:
▼26.5 GHz to 325 GHz (External Mixer)
▼50 GHz to 90 GHz (High Performance Waveguide Mixer)
▲Built-in connector to connect High Performance Waveguide Mixer and External Mixer (MS2830A-044/045)
▼Connector: SMA-J, 50Ω
▼Local Signal Output: 5 GHz to 10 GHz
▼IF Signal Frequency: 1.875 GHz
◆Excellent Dynamic Range:
▲159 dB (at 25 GHz)
▼TOI: ≥+13 dBm
▼DANL: –146 dBm/Hz
▲157 dB (at 40 GHz)
▼TOI: ≥+13 dBm (nom.)
▼DANL: –144 dBm/Hz
◆Preamp up to 43 GHz
▲→ MS2830A-068/168: Microwave Preamplifier
▲DANL: –156 dBm/Hz (at 25 GHz)
▲DANL: –150 dBm/Hz (at 40 GHz)
◆Total Level Accuracy:
▲±0.5 dB (300 kHz ≤ f < 4 GHz)
▲±3.0 dB (13.8 GHz < f ≤ 40 GHz)
◆Used as Wideband Down Converter
▲Built-in IF Output Function (MS2830A-044/045)
▼Connector: SMA-J, 50Ω
▼IF Output Frequency: 1.875 GHz
▼IF Output Bandwidth: 1 GHz (3 dB Bandwidth, nom.)
▼Gain: –10 dB (nom.)
●Improved Level Linearity
◆Reference Oscillator
▲Pre-installed Reference Oscillator
▼Aging Rate: ±1 × 10–7/year, ±1 × 10-–8/day
▼Start-up Characteristics: ±5 × 10-–8 (5 minutes after power-on)
▲Rubidium Reference Oscillator (MS2830A-001/037)
▼Aging Rate: ±1 × 10-–10/month
▼Start-up Characteristics:±1 × 10-–9 (MS2830A-001: 7 minutes after power-on, MS2830A-037: 15 minutes after power-on)
◆Versatile Built-in Functions
▲Channel Power
▲Occupied Bandwidth
▲Adjacent Channel Leakage Power
▲Spectrum Emission Mask
▲Spurious Emission
▲Burst Average Power
▲Frequency Counter
▲AM Depth
▲FM Deviation
▲Multi-marker & Marker List
▲Highest 10 Markers- Limit Line
▲2-tone 3rd-order Intermodulation Distortion
▲ Annotation Display (On/Off)
▲Power Meter
▲ Phase Noise
▲Noise Figure
◆Low-power Consumption
▲MS2830A-044/045: 190 VA (nom.)
●Signal Analyzer Functions
◆Analysis Bandwidth
▲MS2830A-006: 10 MHz max.(20 MHz max. sampling rate = 50 ns resolution, ADC resolution 16 bits)
▲MS2830A-005, MS2830A-009: 31.25 MHz max.(50 MHz max. sampling rate = 20 ns resolution, ADC resolution 16 bits)
▲MS2830A-077: 62.5 MHz max.(100 MHz max. sampling rate = 10 ns resolution, ADC resolution 14 bits)
▲MS2830A-078: 125 MHz max.(200 MHz max. sampling rate = 5 ns resolution, ADC resolution 14 bits)
◆Capture Function
▲Saves analysis Span × Time signal to internal memory and writes to hard disk. Up to 100 Msamples per measurement saved to internal memory.
▼Example: Span 1 MHz: Max. capture time 50 s;Span 10 MHz: Max. capture time 5 s;Span 100 MHz: Max. capture time 0.5 s
◆Replay Function
▲Reads saved data and replays using signal analyzer function.
▼Example:
1. Data sharing between R&D and manufacturing
2. Later laboratory bench-top analysis of on-site signals
◆Measurement with Sub-trace Display
▲Split screen displaying both main and sub-traces at same time to check errors
▼Main: Spectrum, Frequency vs. Time, Power vs. Time, Phase vs. Time, CCDF/APD, Spectrogram
▼Sub: Power vs. Time, Spectrogram
◆Supports 125 MHz Wideband Measurements up to 43 GHz
▲→ MS2830A-067: Microwave Preselector Bypass
▲→ MS2830A-078: Analysis Bandwidth Extension to 125 MHz
▲Bypassing preselector improves RF frequency characteristics and in-band frequency characteristics. Supports modulation analysis and signal analyzer measurements for signals up to 43 GHz.
●BER Measurement Function (MS2830A-026)
◆This option measures BER using Data/Clock/Enable demodulated at the DUT.
▲Input Bit Rate: 100 bps to 10 Mbps
▲Input Level: TTL Leve
●Installing the bandwidth analysis option up to 125 MHz adds signal analyzer functions for checking phenomena that are hard to check using a spectrum analyzer, such as frequency vs. time, phase vs. time, spectrogram, and CCDF. In addition, optional measurement software supports modulation analysis. Moreover, installing a preselector bypass option enables use of the signal analyzer and modulation analysis functions up to 26.5 GHz/43 GHz (MS2830A-044/045). Finally, it can be customized to support a range of application-specific measurements.
◆Installing a microwave-band preamp supports measurement of weaker signals.
◆Using the 1st local signal output as an external mixer supports measurement of high-frequency signals up to 325 GHz.
◆Using the 1st IF signal output as a down converter supports analysis in combination with external equipment
■Key Features:
●Basic Performance/Functions
◆Frequency Range
▲MS2830A-044: 9 kHz to 26.5 GHz
▲MS2830A-045: 9 kHz to 43 GHz
◆Measures up to 325 GHz using High Performance Waveguide Mixer and External Mixer
▲Frequency Range:
▼26.5 GHz to 325 GHz (External Mixer)
▼50 GHz to 90 GHz (High Performance Waveguide Mixer)
▲Built-in connector to connect High Performance Waveguide Mixer and External Mixer (MS2830A-044/045)
▼Connector: SMA-J, 50Ω
▼Local Signal Output: 5 GHz to 10 GHz
▼IF Signal Frequency: 1.875 GHz
◆Excellent Dynamic Range:
▲159 dB (at 25 GHz)
▼TOI: ≥+13 dBm
▼DANL: –146 dBm/Hz
▲157 dB (at 40 GHz)
▼TOI: ≥+13 dBm (nom.)
▼DANL: –144 dBm/Hz
◆Preamp up to 43 GHz
▲→ MS2830A-068/168: Microwave Preamplifier
▲DANL: –156 dBm/Hz (at 25 GHz)
▲DANL: –150 dBm/Hz (at 40 GHz)
◆Total Level Accuracy:
▲±0.5 dB (300 kHz ≤ f < 4 GHz)
▲±3.0 dB (13.8 GHz < f ≤ 40 GHz)
◆Used as Wideband Down Converter
▲Built-in IF Output Function (MS2830A-044/045)
▼Connector: SMA-J, 50Ω
▼IF Output Frequency: 1.875 GHz
▼IF Output Bandwidth: 1 GHz (3 dB Bandwidth, nom.)
▼Gain: –10 dB (nom.)
●Improved Level Linearity
◆Reference Oscillator
▲Pre-installed Reference Oscillator
▼Aging Rate: ±1 × 10–7/year, ±1 × 10-–8/day
▼Start-up Characteristics: ±5 × 10-–8 (5 minutes after power-on)
▲Rubidium Reference Oscillator (MS2830A-001/037)
▼Aging Rate: ±1 × 10-–10/month
▼Start-up Characteristics:±1 × 10-–9 (MS2830A-001: 7 minutes after power-on, MS2830A-037: 15 minutes after power-on)
◆Versatile Built-in Functions
▲Channel Power
▲Occupied Bandwidth
▲Adjacent Channel Leakage Power
▲Spectrum Emission Mask
▲Spurious Emission
▲Burst Average Power
▲Frequency Counter
▲AM Depth
▲FM Deviation
▲Multi-marker & Marker List
▲Highest 10 Markers- Limit Line
▲2-tone 3rd-order Intermodulation Distortion
▲ Annotation Display (On/Off)
▲Power Meter
▲ Phase Noise
▲Noise Figure
◆Low-power Consumption
▲MS2830A-044/045: 190 VA (nom.)
●Signal Analyzer Functions
◆Analysis Bandwidth
▲MS2830A-006: 10 MHz max.(20 MHz max. sampling rate = 50 ns resolution, ADC resolution 16 bits)
▲MS2830A-005, MS2830A-009: 31.25 MHz max.(50 MHz max. sampling rate = 20 ns resolution, ADC resolution 16 bits)
▲MS2830A-077: 62.5 MHz max.(100 MHz max. sampling rate = 10 ns resolution, ADC resolution 14 bits)
▲MS2830A-078: 125 MHz max.(200 MHz max. sampling rate = 5 ns resolution, ADC resolution 14 bits)
◆Capture Function
▲Saves analysis Span × Time signal to internal memory and writes to hard disk. Up to 100 Msamples per measurement saved to internal memory.
▼Example: Span 1 MHz: Max. capture time 50 s;Span 10 MHz: Max. capture time 5 s;Span 100 MHz: Max. capture time 0.5 s
◆Replay Function
▲Reads saved data and replays using signal analyzer function.
▼Example:
1. Data sharing between R&D and manufacturing
2. Later laboratory bench-top analysis of on-site signals
◆Measurement with Sub-trace Display
▲Split screen displaying both main and sub-traces at same time to check errors
▼Main: Spectrum, Frequency vs. Time, Power vs. Time, Phase vs. Time, CCDF/APD, Spectrogram
▼Sub: Power vs. Time, Spectrogram
◆Supports 125 MHz Wideband Measurements up to 43 GHz
▲→ MS2830A-067: Microwave Preselector Bypass
▲→ MS2830A-078: Analysis Bandwidth Extension to 125 MHz
▲Bypassing preselector improves RF frequency characteristics and in-band frequency characteristics. Supports modulation analysis and signal analyzer measurements for signals up to 43 GHz.
●BER Measurement Function (MS2830A-026)
◆This option measures BER using Data/Clock/Enable demodulated at the DUT.
▲Input Bit Rate: 100 bps to 10 Mbps
▲Input Level: TTL Leve