Keysight Infiniium Oscilloscopes Software Release Notes

2021-09-07
▲This software is designed to run on the Keysight Infiniium 9000 Series, S-Series, 90000A Series, 90000 X-Series, V-Series, 90000 Q-Series, and Z-Series oscilloscopes or on personal computers.
●Enhancements
◆Adds support for a new protocol bundle, D9011BDLP - “Basic Infiniium Protocol Decode/Trigger”.
◆Adds support for a new protocol bundle, D9020BDLP– “Complete Infiniium Protocol Decode/Trigger”.
◆Adds new SCPI grammar for returning the phase noise frequency data, :WAVeform:PNOise:FREQuency?
●Bug Fixes
◆Fixes the following issue. Keysight IT recently tightened its Internet security and the Infiniium Software Updater could not reach keysight.com for updates. This manifests as a message in the "Check for Updates" or "Update Software" feature that the "LatestAppinfo.xml file cannot be found", a standard Microsoft error.
◆Updates the help documentation calculations for noise eye-height measurements.
◆Fixes the dynamic range reading for the N5449A High Impedance Adapter.
◆Fixes an issue with the :CHANNEL[N]:PROBE:INFO query returning incorrect probe information.
◆Fixes an issue with Infiniium going into a “no measurement” state for the N6472A IEEE 802.3 bs/cd compliance test application.
◆Fixes -222 “Data out of range” error for the :MEASURE:THRESHOLD:PERCENT command.
◆Fixes a delta time measurement issue for the Add math function when the two sources being added are the same channel.
◆Fixes an issue with the PAM4 jitter and histogram measurement results degrading with each setup change.
◆Fixes the following issue. After running the PCIe protocol decoder on a waveform containing TS1 Training Sequences, the decoder erroneously shows "Compliance Receive = Enable Compliance Receive" in the "Details" view of a packet. This logic is inverted.
◆Fixes an EZJIT MATLAB runtime error when running the Rx DisplayPort compliance test solution for HBR3 Total Jitter.
◆Fixes an issue with the :MTES:FOLD:TSC command was returning -222 “Data out of range” for the Rx MIPI D-PHY compliance test solution.
◆Fixes an issue with the :LANE[N]:EQUALIZER:DFE:TAP:AUTOMATIC command returning error 25, “This entry isn’t a valid selection. The control had not been modified.”
◆Fixes an issue with a “current probe” selection always picking N7019A.
◆Fixes an issue with information messages showing up in the screen shot obstructing the waveform viewing area.

Keysight

9000 Series9000S-Series90000A Series90000A90000 X-SeriesV-Series90000 Q-SeriesZ-Series

More

Part#

Oscilloscopes Software

More

More

Development Environment(Software/Firmware)

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

25 June, 2020

1.7 MB

- The full preview is over. If you want to read the whole 73 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: