Keysight UXR Oscilloscopes Software Release Notes

2021-08-20
■This software is designed to run on the Keysight Infiniium UXR-Series oscilloscopes and supports the following model numbers, UXR0134A, UXR0164A, UXR204A, UXR0254A, UXR0334A, UXR0402A, UXR0404A, UXR0502A, UXR0504A, UXR0592A, UXR0594A, UXR0702A, UXR0704A, UXR0252AP, UXR0254AP, UXR0402AP, UXR0404AP, UXR0592AP, UXR0594AP, UXR0702AP, UXR0704AP, UXR0802A, UXR0804A, UXR1002A, UXR1004A, UXR1102A, UXR1104A, and UXR0051AP.
▲Version 10.25.00702 (Patch 1)
●Enhancements
◆Provides support for the N7005A 60GHz O/E Converter.
●Bug Fixes
◆Fixes issues impacting the BitifEye N5991 HDMI 2.1 Receiver Test including Data Jitter Calibration and Cable Inter-Pair Skew Test failures.
◆Fixes an issue causing the UXR to hang while running the BitifEye N5991 USB4 1.1 Receiver Test.
◆Fixes the Auto Deskew feature for differential channels when running with a channel bandwidth filter enabled.
◆Fixes an issue restoring the default setup behavior for channel voltage units after running the N7004A O/E Converter dark cal.
◆Fixes an issue when selecting a Current probe. It was always selecting N7019A.
◆Fixes the control button functions for the N2750A/51A/52A InfiniiMode Differential Active Probes.
◆Fixes an issue with loading a composite file saved from a differential channel waveform. Sometimes, only part of the waveform was loaded.
◆Fixes an issue with incorrectly reporting dynamic range when using the N5449A High Impedance adapter.
◆Fixes the deskew channel control in the Phase Noise application setup wizard. It was failing for cases when the edge direction was set to Both.
◆Fixes the Help->”Check for Updates...” feature.
◆Fixes an issue preventing an AC Gain setting great than 1 for CTLE equalization.
◆Fixes an issue with the Auto Setup feature for the MIPI D-PHY Protocol Decode application causing ADC clipping. Changing the voltage offset to eliminate the clipping caused the decoder to quite decoding or worse, the oscilloscope application to crash.
◆Fixes an issue where the lane index was not being setup properly for in-place DFE.

Keysight

UXR0134AUXR0164AUXR204AUXR0254AUXR0334AUXR0402AUXR0404AUXR0502AUXR0504AUXR0592AUXR0594AUXR0702AUXR0704AUXR0252APUXR0254APUXR0402APUXR0404APUXR0592APUXR0594APUXR0702APUXR0704APUXR0802AUXR0804AUXR1002AUXR1004AUXR1102AUXR1104AUXR0051APN7005AN5991N5449A

More

Part#

Oscilloscopes Software

More

More

Development Environment(Software/Firmware)

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

17 July 2020

429 KB

- The full preview is over. If you want to read the whole 12 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: