MODEL KBSI-240D Signal Isolator KB Part No. 9431
The KBSI-240D is versatile since it can accommodate a wide range of input voltages (0 - 25*,0 - 120 and 0 - 550V DC) and, in addition, a wide range of input current signals (4 - 20 mA,10 - 50 mA and 1 - 5 mA). The Voltage/Current (“VLT/CUR”) jumper is used to change the KBSI-240D from a voltage to current input.
A built-in power supply enables the KBSI-240D to be controlled with a 5KΩ remote poten-tiometer (connect potentiometer to terminals “P1,” “5” and “6” – see page 9). The potentiome-ter can also be wired for Auto/Manual Operation.
*The input range of 0 - 25V is the maximum voltage that can be applied to terminals “5” and“6”. The minimum input voltage is 0 - 5 volts, which can achieve an output voltage of 0 - 10volts. The unit is factory calibrated so that a 0 - 10V DC input yields a 0 - 10V DC output.
|
|
User's Guide |
|
|
|
Please see the document for details |
|
|
|
|
|
|
|
English Chinese Chinese and English Japanese |
|
9/7/2010 |
|
Rev. E |
|
A40255 |
|
1.5 MB |