N32G457VEL Human Body Model (HBM) ELECTROSTATIC DISCHARGE (ESD) TESTING REPORT(S200428109)
●Reference: MIL-STD-883K / Method 3015.9
●Temperature: 25 ± 5 °C ; Humidity: 55 ± 5%
●Test Voltage: ±3000V~±4000V,Step:±500V
●Failure Criteria: After testing, DUT no longer fulfills requirements of ± 30% voltage drift at ± 1uA reference current and compliance within 10% V+I envelope around REFERENCE I-V curve (pre-zap).
●ESD Testing Result: Minimum Pass Level = ±4000V
|
|
|
|