RX110 Group Initial Setting APPLICATION NOTE

2020-12-28
This document describes settings required after a reset such as clock settings, stop processing for active peripheral functions after a reset, and nonexistent port initialization according to usage conditions selected in the header files.
Clocks are configured in the following steps:
1. Sub-clock setting (including the associated RTC settings)
2. Main clock setting
3. HOCO clock setting
4. System clock switching
In this application note, the clock settings are switched by changing the constants defined in r_init_clock.h. In the sample code, the main clock is used as the system clock, and the sub-clock and RTC are not used. Change the constant to select the required clock setting.
The port direction registers which have nonexistent ports need to be specified with determined values. After the nonexistent port initialization function is called, when writing in byte units to the PDR registers or PODR registers which have nonexistent ports, set the corresponding bits for nonexistent ports as follows: set the values listed in Table 4.2 and Table 4.3 to the I/O select bits in the PDR registers, and set the output data store bits in the PODR registers to 0.

Renesas

RX110RF51105ADFM

More

Part#

MCU

More

More

Application note & Design Guide

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

Sept.19.19

Rev. 1.02

R01AN1850EJ0102

1.8 MB

- The full preview is over. If you want to read the whole 38 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: