【PCN】Silicon Labs BGX13P Errata Version 0.1 Release / BGX13S Errata Version 0.1 Release (200609776)
●Description of Change:
Silicon Labs is pleased to announce the release of the following errata versions for BGX13P and BGX13S devices.
Release of Version 0.1 of the BGX13P Errata.
Release of Version 0.1 of the BGX13S Errata.
BGX13P and BGX13S products running firmware version 1.2.2045.0 and earlier are affected by this errata during any entrance into low power mode, which can occur when a system is running the UART baud rate at 9600 or explicitly entering sleep mode through the command set. To avoid the issue, systems should use a baud rate of 9600 or higher, and systems should avoid BGX13 sleep mode entrance. Firmware version 1.2.2376.1 includes a fix for the issue. This version of firmware is available today through an over-the-air update in the BGX Commander app and supporting Xpress mobile framework. A DFU serial programming utility is also available upon request.
●Reason for Change:
Errata item BGX13_E101 - Potential for Infrequent Device Reset.
BGX13P 、 BGX13S 、 BGX13 、 BGX13P22GA-V21 、 BGX13P22GA-V21R 、 BGX13P22GA-V23 、 BGX13P22GA-V23R 、 BGX13S22GA-V21 、 BGX13S22GA-V21R 、 BGX13S22GA-V31 、 BGX13S22GA-V31R |
|
|
|
|
|
PCN/EOL |
|
|
|
Please see the document for details |
|
|
|
|
|
|
|
English Chinese Chinese and English Japanese |
|
6/9/2020 |
|
|
|
200609776;2020-06-09-776 |
|
696 KB |