750-495/040-00x 3-Phase Power Measurement Module 690 V 3-Phase Power Measurement; AC 690 V; extreme

2020-05-20

The 750-495/040-00x 3-Phase Power Measurement Module (also referred to by the short name “I/O module”) allows measurement of electrical data in a 3-phase supply network.
The I/O module provides a large number of measured quantities, allowing comprehensive analysis of the 3-phase network. These measured values allow the operator optimized control of the supply to a drive or machine, protecting the system from damage and failure.
The measured values provided indicate the load type (inductive or capacitive) and whether it is an energy consumer or producer, for example. This allows e.g. visualization as a 4-quadrant display, as has been implemented in the display of the measured values in WAGO-I/O-CHECK.
The voltages of the three phases are connected to CAGE CLAMP® connections L1, L2, L3 and N, the currents are connected via current transformers to CAGE CLAMP®connections I1+ and I1−, I2+ and I2−, I3+ and I3− and IN+ and IN−, or via Rogowski coils to CAGE CLAMP®connections RC1+ and RC1−, RC2+ and RC2−, RC3+ and RC3− and RCN+ and RCN−. On the basis of these input signals, the I/O module determines the various AC measured quantities, such as voltage and current, reactive, apparent and effective power, energy consumption, power factor, phase angle and frequency. Harmonic analysis (current/voltage) is also possible for a selectable phase up to the 41st harmonic. The measured quantities are available in the process image, without requiring high processing power from the controller.
In firmware versions 05 and above, the I/O module offers the option of distinguishing the following topologies:
• “4-Wire Wye” (default) for the measurement on 3 line conductors in 3-phase and 1-phase networks with a neutral conductor.
• “3-Wire Wye/Delta for the measurement in 3-phase networks without a neutral conductor using the 2-wattmeter method (Aron circuit/Blondel’s Theorem).
• “4-Wire Wye, 2 Phases” for the measurement on 2 line conductors in3-phase networks with a neutral conductor.
• “Artificial Star Point” for the measurement in 3-phase networks without a neutral conductor using the 3-wattmeter method (ASP).
You can find information on the possible connection diagrams in the sections“Power Measurement with 4-Wire Connection on Y Networks” and “Power Measurement with 3-Wire Connection on Y/Δ Networks.”
Each of these sections is followed by sections describing the measured values provided.

WAGO

750750-495/040-00x750-495/040-001750-495/040-002750-495/040-000750-538758-910750-606750-625/000-001750-642

More

Part#

3-Phase Power Measurement Module

More

More

User's Guide

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

2020/04/25

Version 1.2.0

27.7 MB

- The full preview is over. If you want to read the whole 312 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: