CPC1394G IXYS ICD Product Change Notification (PCN)

2022-04-08

■Detailed Description of Changes:
●IXYS Integrated Circuits Division (ICD), now part of Littelfuse, has made design enhancements to the CPC1394G to improve package integrity when subjected to the more demanding mechanical stresses caused by some solder reflow processes.
●To facilitate increased device robustness, the package mold compound has been upgraded and design improvements have been made to the leadframe. This will enable the CPC1394G to withstand the diverse solder reflow profiles in production today.
●During the engineering requalification procedure an additional LED was evaluated to ensure security of supply of this high volume product. Because this supplementary LED has a slightly greater forward voltage rating, the maximum “LED Forward Voltage“ specification in the CPC1394 data sheet will change from: 1.4V to 1.5V with I_F=5mA.
●As part of the requalification process, a review of the data sheet revealed an anomaly in the load current specification. The CPC1394G, originally designed for the pulsed output function provided by smart meters such as those deployed in Europe, had a pulsed load current specification typically not provided in solid state relay data sheets. This 120mA rating was unintentionally listed as the steady state load current rather than a pulsed load current specification. The CPC1394G maximum steady state load current specification of 90mA has been added to the data sheet along with an On-resistance specification at 90mA. Please review the updated data sheet for device pulse current capabilities and steady state performance. These load-current and on-resistance specification changes are not a result of any modifications to the device. Products designed and built based on the previous data sheet specifications are not expected to perform less effectively with the improved leadframe and mold compound.
■Reason for Change:
●Leadframe and mold compound package design improvements will result in enhanced solder reflow performance and product reliability. This change is a result of our ongoing effort and commitment to continuous quality improvement of our products.
●Change to the data sheet maximum LED Input Voltage Drop is to safeguard security of supply of this high volume product.
●Load current and On-resistance data sheet specification changes are to clarify device capability and performance.

IXYS

CPC1394GCPC1394GVCPC1394GRCPC1394GRTR

More

Part#

More

More

PCN/EOL

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

December 13, 2019

PCN1073

168 KB

- The full preview is over,the data is 2 pages -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: