KX022 and KX023 Supplemental Offset Calibration

2022-04-20

●Introduction
■Kionix calibrates the offset of the KX022 and KX023 at the factory. After assembly, it is sometimes found by the customer that there is a subsequent offset shift.
■The KX022 and KX023 have embedded registers used to provide a final factory calibration. These registers have the default factory calibration but also they can be adjusted by a user programmatically for an additional offset adjustment to the original factory programmed calibration.
■The values for the user applied offset adjustment are stored in RAM and must be updated by the controlling system after each power up or reset.
■Offset Calibration readings and adjustments are calculated using 2g High RES mode.
■The Offset calibration adjustment adds a constant value to correct for an offset error.
■Two registers are employed to make the Offset Calibration adjustment.

Kionix

KX022KX023

More

Part#

More

More

Application note & Design Guide

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

21 July 2015

AN 046

255 KB

- The full preview is over. If you want to read the whole 5 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.