Wire Mesh EMI Gasket Selection Guide
●Ferrex® is Parker Chomerics tradename for tin-plated, copper-clad steel wire per ASTM B-520, ASTM (QQ-W-343) tin-plated, 2-3% by weight; ASTM B-227 copper-cladding 30-40% by weight; SAE 1010 steel wire, balance by weight and is the same as Tecknit Su/Cu/Fe which it replaces.
●Two versions have fins especially designed for easy attachment.
●Most products for which this method is suitable are available with ''dry back'' (solvent-activated) adhesives already applied.
●Available without elastomer in metal form only.
●These EMI ratings are based on MIL-STD-285 test methods and are useful for making meaningful qualitative comparisons between products in this table since all tests were conducted under similar conditions. They cannot be used to compare to other EMI gasket data unless those data were obtained by the same methods.
●Non-conductive RTV yields excellent results, but use sparingly. If more adhesive surface is needed, use conductive adhesive.
●Available with COMBO POLA only
|
|
Quick Reference Guide |
|
|
|
Please see the document for details |
|
|
|
|
|
|
|
English Chinese Chinese and English Japanese |
|
April 2013 |
|
|
|
TB 1103 EN |
|