■Detailed Description of Change:
●The data sheet LED Input Voltage Drop (V_F) maximum specification of these products has changed from 1.4V to 1.5V.For most devices, the Forward Current (I_F) test condition at which the Input Voltage is measured is I_F=5mA. For the LCA210 family of parts, the test condition has changed from I_F=8mA to I_F=10mA while the test condition of the LCA220 family of parts remains unchanged at I_F=10mA.See the tables below for clarification. The forward voltage (V_F) increase is necessary to ensure the security of supply due to high demand of these products.
■Reason for Change:
●The change in maximum LED Input Voltage Drop to ensure security of supply required specification relief.Change to the forward current test condition is to improve manufacturing quality and consistency by reducing the number of unique test conditions to be monitored for the LED Input Voltage Drop parameter across all product lines.