TDM 45 series High power test and diagnostics combination for medium voltage cables
■Enables standard compliant high power VLF testing at 0.1 Hz (5 μF @ 40 kVrms)
■Internal tanDelta measurement with automatic result interpretation
■Partial discharge diagnosis using VLF Sine wave, Damped AC or50/60 Hz Slope technology voltages
| 世强硬创平台www.sekorm.com | |
| 世强硬创平台电子商城www.sekorm.com/supply/ | |
| 世强硬创平台www.sekorm.com | |
| 世强硬创平台www.sekorm.com |
- +1 Like
- Add to Favorites
All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.
Recommend
Effective commissioning tests on HV and EHV cables ELECTRICAL TESTER
October 2014 - Supplier and Product Introduction
MIT485,SVERKER900,S1 SERIES,S1
UNDERGROUND CABLES: preventing failure with partial discharge testing ELECTRICAL TESTER
August 2015 - Supplier and Product Introduction
SF6
When things go wrong: A new solution for locating faults on long cables ELECTRICAL TESTER
March 2017 - Supplier and Product Introduction
MIT515
TDM 45 Series The NEW high power test and diagnosis combination for MV cables Technical data
2019/11/24 - Datasheet
890017909,TDM 45-P-PD,890010915,90007366,1007578,1007579,2003886,1004629-S,TDM 45-P-TD,890015603,1007572,1007573,1007574,890023555,1007577,128300045-S,128311799,PDS 60 PD,TDM 45,138316309,TDM 4540-P,820016302,90011938,820016301,TDM 4540-P-PD,TDM 4540,TDM 4540-P-TD,118306900,2004421,138316094,TDM 45-P,2004420,2005655,1007581,VLF CR-40-TB,1007582,PDS 60,128311042,TDM 45-P-TD-PD,138316310,128311801,TDM 4540-P-TD-PD,128311800,1007580,1003380
Cable Identifier Reliable cable selection for energised and de-energised cables
2021/9/30 - Datasheet
118304682,1005669-1,820013106,820014535,820013107,90020744,1005670-1,1005671-1,1005672-1,1005673-1,2008761,90020743,2008762,90020175,820025178,2011453
查看更多版本Testing, diagnostics and fault location on power cables
2021/08/21 - Selection guide
DIGIPHONE+2,EZ-THUMP,VLF SINE 62-TD,VLF SINE 34 KV,SMARTFUSE 2,TELEFLEX SERIES,HVB10,TDS NT SERIES,TDR2050,STX,TDS NT,EZ-THUMP SERIES,SFX 12,HV DAC-200,VLF CR 28 KV,TDM 45,STX VAN,FERROLUX FLG50,SPG 5-1000,MTDR300,SPG 5,SMART THUMP,TDS 60,TDM 45-P,TELEFLEX,MFM10,DIGIPHONE+2 NT SET,DIGIPHONE+2 NTRX SET,SWG 32,SFX FAMILY,LCI,CENTRIX 2.0,TELEFLEX VX,VLF CR 40 KV,VLF SINE 45-TD,SMART THUMP SERIES,PIL 8,MV DAC-30,FAULT SNIFFER 2,PD DETECTOR PDS 60,PD SCAN,NIM 1000,EXT. TANDELTA,VLF CR 60-HP,TELEFLEX SX-1,HV DAC-300,SFX SERIES,FERROLUX FLG12,FLG12,VLF CR 60 KV,SFX 32,E-TRAY,TDS 40,TDM 4540-P,SFX,SFX 16,CI,STX40,EASYLOC,PDS 62-SIN,TDM 45 SERIES,VLF SINE 62 KV,UZ 100,VLF CR-80,R30 2.0,VLF CR 80 KV,UHF PDD,VLF SINE 45 KV,PVS100I
MV DAC-30 Test and diagnosis system for medium voltage cables
2021/08/30 - Datasheet
MV DAC-30,1006132-S
查看更多版本Reliable cable selection for energised and de-energised cables
2020/04/01 - Datasheet
11 830 4682,200 8762,9 002 0175,200 8761,100 5671-1,100 5672-1,100 5670-1,9 002 0744,9 002 0743,82 002 5178,100 5669-1,82 001 3106,82 001 3107,201 1453,100 5673-1,200 7615,82 001 5535
Dielectric Spectroscopy for Diagnostics of Water Tree Deteriorated XLPE Cables
2021/08/27 - Application note & Design Guide
1-phased test system with manual operating mode selection
2019/9/23 - Datasheet
VLF CR 60,VLF CR 40,TDM 4540
VLF Sinus 54 kV Test system for medium-voltage cables
2021/6/14 - Datasheet
100 4629-S,89 002 7100,12 831 0950-S,89 002 7200,82 002 0283,100 7582
查看更多版本1-phased test system with automatic operating mode selection and optional 3-phased LV measurement
2019/9/23 - Datasheet
VLF CR 60,VLF CR 40,TDM 4540
EZ-THUMP™ 3 kV & 4 kV Models V2 Portable Cable Fault Location Systems for Low Voltage Cables
2021/08/21 - Datasheet
EZT3DV2-,EZT4V2-
查看更多版本Electronic Mall
Integrated Circuits
Discrete Components
Connectors & Structural Components
Assembly UnitModules & Accessories
Power Supplies & Power Modules
Electronic Materials
Instrumentation & Test Kit
Electrical Tools & Materials
Mechatronics
Processing & Customization