Page 1/4
Description
Position sensors X125
Linear inductive position sensor
X125
As a leading supplier of linear, rotary, tilt and intrinsically safe position sensors, we have the expertise to supply a sensor to suit
a wide variety of applications. Our X125 LIPS (Linear Inductive Position Sensor) incorporates electronics system EX07 which is
ATEX / IECEx approved for use in potentially explosive gas/vapour atmospheres. The X125 is designed to provide feedback for
arduous underwater applications, such as ROVs, where hazardous surface conditions may exist. It remains an affordable,
durable, high-accuracy position. The unit is highly compact and space-efficient, being responsive along almost its entire length.
Like all similar sensors, the X125 provides a linear output proportional to displacement. Each sensor is supplied with the output
calibrated to the travel required by the customer, from 5 to 800mm and with full EMC protection built in. The sensor is very
robust, the body and push rod being made of stainless steel for long service life and environmental resistance. Overall
performance, repeatability and stability are outstanding over a wide temperature range. The sensor is easy to install with
mounting options including M8 rod eye bearings and body clamps. The push rod can be supplied free or captive, with male M8
thread, an M8 rod eye, or dome end, Captive push rods can be sprung loaded, in either direction, on sensors up to 300 mm of
travel. The X125 also offers a range of mechanical options, environmental sealing is to IP68 350 Bar.
350 bar submersible stand-alone linear Position sensor
Intrinsically Safe for Hazardous Gas/Vapour Atmospheres
· Intrinsically safe for Gas to: Ex II 1G
· Travel set to customer’s requirement
· Compact and self-contained
· High durability and reliability
· High accuracy and stability
· Sealing to IP68 350 Bar
Specifications
Dimensions
Body diameter 40 mm electronics and 35 mm
Body length (Axial version) measurement length + 184 mm
Body length (Radial version) measurement length + 189 mm
Push rod extension measurement length + 7 mm, OD 12.6 mm
For full mechanical details see drawing X125-11
Power Supply +5V dc nom. ± 0.5V, 10mA typ 20mA max
Output Signal 0.5-4.5V dc ratiometric, Load: 5kΩ min.
Independent Linearity ≤ ± 0.25% FSO @ 20°C - up to 450 mm
≤ ± 0.5% FSO @ 20°C - over 450 mm
≤ ± 0.1% FSO @ 20°C* available upon request.
*
Sensors with calibrated travel from 10 mm up to 400 mm.
Temperature Coefficients < ± 0.01%/°C Gain &
< ± 0.01%FS/°C Offset
Frequency Response > 10 kHz (-3dB)
Resolution Infinite
Noise < 0.02% FSO
Intrinsic Safety Ex II 1G
Ex ia IIC T4 Ga (Ta= -40°C to 80°C)
Approval only applies to the specified ambient temperature range and atmospheric
conditions in the range 0.80 to 1.10 Bar, oxygen ≤ 21%
Sensor Input Parameters Ui: 11.4V, Ii: 0.20A, Pi: 0.51W.
(without cable) Ci: 1.16µF, Li: 50µH
(with cable) Ci: 1.36µF, Li: 860µH with 1km max. cable
09.2017 | version 20170524 - Rev 17b