Page 1/4
Description
Position sensors X117
Linear inductive position sensor
X117
This X117 LIPS® (Linear Inductive Position Sensor) is designed for industrial and scientific feedback applications and is ideal for
OEMs seeking good sensor performance for arduous applications in hazardous areas.
Overall performance, repeatability and stability are outstanding over a wide temperature range. The unit is very compact nd
space-efficient with a small 19 mm diameter body. The sensor is very robust, the body and push rod being made of stainless steel.
The sensor is easy to install with mounting options including M5 male stud and M5 rod eye bearing. The push rod can be supplied
free or captive, with male M5 thread or M5 rod eye. Like LIPS® sensors, the X117 provides a linear output proportional to
displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 10 to 300 mm and with
full EMC protection built in. The X117 offers a range of mechanical options, environmental sealing is to IP67.
Sensor must be used in conjunction with Galvanic Isolation Amplifier X005!
Slim-Line Linear Position Sensor,
Intrinsically Safe for Hazardous Gas/Vapour Atmospheres
· Measurement ranges from 0 … 10 mm to 0 … 300 mm
· Linearity ±0.25 %
· Supply voltage and output signal via Galvanic Isolation Amplifier X005
· Intrinsically Safe for Gas to: Ex II 1G
05.2016 | version 201504 - Rev 2.01
Specifications
Measurement Ranges: 0 … 10 mm to 0 … 300 mm, factory-set, in increments of 1 mm
Power Supply
(via Galvanic Isolation Amplifier X005)
: +5 VDC nom. ±0.5 V, 10 mA typ, 20 mA max.
Output Signal
(to Galvanic Isolation Amplifier X005)
: 0.5 … 4.5 V ratiometric, load min. 5 kΩ
Independent Linearity at 20 °C: <±0.25 % for ranges up to 450 mm
Temperature Coefficient Gain: <±0.01 %/K
Temperature Coefficient Offset: <±0.01 % FS/K
Frequency Range: 0 ... >10 kHz (-3 dB)
Resolution: Infinite
Noise: <0.02 % FSO
Intrinsic Safety: Ex II 1G
Ex ia IIC T4 Ga (Ta = -40 … +80 °C)
Sensor Input Parameters: Ui = 11.4 V, Ii = 0.20 A, Pi = 0.51 W
Connector: Ci = 1.16 µF, Li = 50 µH
Cable: Ci = 1.36 µF, Li = 860 µH, cable length max. 1000 m
Operating Temperature Range: -40 … +80 °C
Storage Temperature Range: -40 … +125 °C