Page 1/4
Description
Position sensors X117
Linear inductive position sensor
X117
This X117 LIPS® (Linear Inductive Position Sensor) is designed for industrial and scientific feedback applications and is ideal for
OEMs seeking good sensor performance for arduous applications in hazardous areas.
Overall performance, repeatability and stability are outstanding over a wide temperature range. The unit is very compact nd
space-efficient with a small 19 mm diameter body. The sensor is very robust, the body and push rod being made of stainless steel.
The sensor is easy to install with mounting options including M5 male stud and M5 rod eye bearing. The push rod can be supplied
free or captive, with male M5 thread or M5 rod eye. Like LIPS® sensors, the X117 provides a linear output proportional to
displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 10 to 300 mm and with
full EMC protection built in. The X117 offers a range of mechanical options, environmental sealing is to IP67.
Sensor must be used in conjunction with Galvanic Isolation Amplifier X005!
Slim-Line Linear Position Sensor,
Intrinsically Safe for Hazardous Gas/Vapour Atmospheres
· Measurement ranges from 0 … 10 mm to 0 … 300 mm
· Linearity ±0.25 %
· Supply voltage and output signal via Galvanic Isolation Amplifier X005
· Intrinsically Safe for Gas to: Ex II 1G
05.2016 | version 201504 - Rev 2.01
Specifications
Measurement Ranges: 0 … 10 mm to 0 … 300 mm, factory-set, in increments of 1 mm
Power Supply
(via Galvanic Isolation Amplifier X005)
: +5 VDC nom. ±0.5 V, 10 mA typ, 20 mA max.
Output Signal
(to Galvanic Isolation Amplifier X005)
: 0.5 … 4.5 V ratiometric, load min. 5 kΩ
Independent Linearity at 20 °C: <±0.25 % for ranges up to 450 mm
Temperature Coefficient Gain: <±0.01 %/K
Temperature Coefficient Offset: <±0.01 % FS/K
Frequency Range: 0 ... >10 kHz (-3 dB)
Resolution: Infinite
Noise: <0.02 % FSO
Intrinsic Safety: Ex II 1G
Ex ia IIC T4 Ga (Ta = -40 … +80 °C)
Sensor Input Parameters: Ui = 11.4 V, Ii = 0.20 A, Pi = 0.51 W
Connector: Ci = 1.16 µF, Li = 50 µH
Cable: Ci = 1.36 µF, Li = 860 µH, cable length max. 1000 m
Operating Temperature Range: -40 … +80 °C
Storage Temperature Range: -40 … +125 °C
Environmental Sealing: IP67
EMC Performance: EN61000-6-2, EN61000-6-3
Vibration, max.: IEC 68-2-6: 10 g
Shock, max.: IEC 68-2-29: 40 g
MTBF: 350000 hours, 40 °C, Gf
Electrical Connection: Connector or 0.5 m cable
Sensor and Galvanic Isolation Amplifier X005 have to
be calibrated altogether at the factory!
Galvanic Isolation Amplifier Output
X005-425 4 … 20 mA
X005-426 20 … 4 mA
X005-525 0.5 … 9.5 V
X005-526 9.5 … 0.5 V
Connector/Cable Options:
-J Axial connector, IP67
-K Radial connector, IP67
-L50 Cable with axial gland, IP67, 50 cm
-I50 Cable with radial gland, IP67, 50 cm
Other cable lengths up to max. 15000 cm available
Other Options:
-N M5 eye rod bearing on body (radial versions only)
-U M5 eye rod bearing on push rod
-V Free push rod (non-captive)
Cable (Options Lxx or Ixx):
3-core screened PUR cable, 0.2 mm², Ø 4 mm, standard
length 50 cm, max 150 m
Connector: maximum conductor cross section 0.75 mm²
Connections
Cable Connector
Red Pin 1 + supply voltage
Black Pin 3 0 V
White Pin 2 Output signal
Screen Pin 4 Body
It is imperative position sensor LIPS X117 be used in
conjunction with a galvanic barrier X005.
The Galvanic Isolation Amplifier X005 will compensate
for up to 15 Ohms resistance in each conductor, this
imposes the following minimum cable sizes:
Cross Section Cable Length
0.25 mm² Up to 150 m
0.5 mm² 150 … 300 m
0.75 mm² 300 … 450 m
1.0 mm² 450 … 600 m
1.5 mm² 600 … 900 m
2.0 mm² 900 … 1000 m
Note: The maximum cable length as specified in the
sensor’s certification takes precedence and must not be
exceeded.
For cable lengths exceeding 10 m a 5-wire connection is recommended to eliminate errors introduced by cable resistance
and associated temperature coefficients. (see data sheet Amplifier X005)
Page 2 /4
05.2016 | version 201504 - Rev 2.01
Options
Electrical Connection