UBX-17022983 IN Information Note TOBY-L200-03S, TOBY-L210-03S, TOBY-L280-03S,
MPCI-L200-03S, MPCI-L210-03S, MPCI-L280-03S:
Release to Production
Page 1 of 3
locate, communicate, accelerate
IN Information Note
Topic:
TOBY-L200-03S, TOBY-L210-03S, TOBY-L280-03S,
MPCI-L200-03S, MPCI-L210-03S, MPCI-L280-03S:
Release to Production
UBX-17022983
Author:
Drazen Drinic
Date:
23-Jun-2017
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express permission is strictly prohibited. © 2017 u-blox ag.
1 Affected Products
Product Name
Order Number
Type No
Firmware version
TOBY-L200
TOBY-L200-03S
TOBY-L200-03S-00
Modem: 15.90
Application: A01.50
TOBY-L210
TOBY-L210-03S
TOBY-L210-03S-00
Modem: 15.63
Application: A01.50
TOBY-L280
TOBY-L280-03S
TOBY-L280-03S-00
Modem: 15.63
Application: A01.50
MPCI-L200
MPCI-L200-03S
MPCI-L210-03S-00
Modem: 15.90
Application: A01.50
MPCI-L210
MPCI-L210-03S
MPCI-L210-03S-00
Modem: 15.63
Application: A01.50
MPCI-L280
MPCI-L280-03S
MPCI-L280-03S-00
Modem: 15.63
Application: A01.50
2 Type of Change
[ ] Hardware modification
[ X ] Firmware update
[ X ] Documentation update
3 Description of Change
Newly implemented features and known limitations are listed in Annex A, B, C.
The following documents have been modified:
Data sheet [1], [2]
AT command manual [3]
System Integration Manual [4]
4 Schedule
This information is effective as of 23
rd
June, 2017.
5 Reference Documents
[1] TOBY-L2 Data Sheet, u-blox Document UBX-13004573-R23
[2] MPCI-L2 Data Sheet, u-blox Document UBX-13004749-R17
[3] u-blox AT Commands Manual, u-blox Document UBX-13002752-R52
[4] TOBY-L2 / MPCI-L2 System Integration Manual, u-blox document UBX-13004618-R23
[5] TOBY-L2 / MPCI-L2 Initial Production Information Note , u-blox Document UBX-15029946
UBX-17022983 IN Information Note TOBY-L200-03S, TOBY-L210-03S, TOBY-L280-03S,
MPCI-L200-03S, MPCI-L210-03S, MPCI-L280-03S:
Release to Production
Page 2 of 3
locate, communicate, accelerate
Annex
A New features and interfaces in this version
For detailed description of the new features and interfaces, see the TOBY-L2 Data Sheet [1], MPCI-L2 Data Sheet
[2], u-blox AT Commands Manual [3], TOBY-L2 / MPCI-L2 System Integration Manual [4].
Interface to WiFi module
WEP security
New configuration file must be applied for ELLA-W1 to comply with current FCC
grant and ETSI regulation.
SAP
SIM Access Profile (SAP)
TOBY-L2 / MPCI-L2 "02S" product versions can be updated to the TOBY-L2 / MPCI-L2 "03S" product versions.
B Restrictions compared to specifications
B.1 Hardware
No restrictions or limitations.
B.2 Features / Firmware / Software
The following AT commands are not functional and must not be used: +UCELLLOCK.
+UCGED: the parameter <mmeCode> is not reliable.
Warning: Flashing a FW image not provided by u-blox will cause the module to crash.