2 of 4
CLADDING (Copper, Alu minum or Bra ss)
Copper 7440-50-8 231-159-6 Varies 1 mg/m
(dust and mist)
1 mg/m
(dust and mist)
Not Classified Under 67/548/E EC
Aluminum 7429-90-5 231-072-3 Varies 5 mg/m
(Resp. Dust)
1 mg/m
(Resp. Dust)
Not Classified Under 67/548/E EC
(only Al powder is Classified)
Zinc (Component of
Brass)
7440-66-6 231-175-3 Varies 5 mg/m
(ZnO fume)
2 mg/m
(as ZnO)
Not Classified Under 67/548/E EC
4. FIRST-AID MEASURES
INHALATION: (Dust & Fume) Remove to fresh air. Obtain medical attention if symptoms
persist.
EYE CONTACT: (Dust) Flush immediately with large amounts of water for 15 to 20 minutes. Do
not rub eye s. Obtain medi cal attent ion if sym ptoms pe rsist.
SKIN CONTACT: (Dust) Remove contaminated clothing and flush area with water for 15 to 20
minutes. Obtain medical attention if symptoms persist.
INGESTI ON: (Dust) Not a likely route of entry – o btain medical at tention.
5. FIRE-FIGHTING MEASURES
FLASH POINT: NE
o
C (
o
F) Flammable Limits: NE
AUTOIGNITION TEMPERATURE: NE
o
C (
o
F)
EXTINGUISHING ME DIA: X Water Spray X Foam X CO
2
X Dry Chemical X Other –
SPECIAL FIRE FIGHTING
PROCEDURES:
Decomposition in a fire may produce toxic fumes. Firefighters should be
equipped with self-contained breathing apparatus and turnout gear.
UNUSUAL FIRE AND EXPLOSION
HAZARDS:
None known.
6. ACCIDENTAL RELEASE MEASURES
PERSONAL PRECAUTIONS: In case of fire toxic fumes are emitted. Wear suitable protective equipment. Do
not breath e dust. Elimi nate so urces of ignition. Avoid contact with skin and
eyes.
ENVIRONMENTAL PRECAUTIONS: Prevent from entering sewer system, surface water or soil.
CLEANING METHODS: Sweep or shovel into appropriate container for disposal. Avoid creation of
airborne dust.
7. HANDLING AND STORAGE
HANDLING: Wear suitable protective equipment, refer to Section 8.
STORAGE: Keep in a cool, well-ventilated area.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
RESPIRATORY PROTECTION: None needed under normal conditions. If mechanical ventilation is absent or
inadequate to maintain exposure levels below those listed in Section 2, use
NIOSH/MSHA approved respirators. A qualified individual should evaluate
each situation.
VENTILATION
LOCAL: Recommended for all industrial operations.
GENERAL: Recommended for all industrial operations.