2
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72V01/72V02/72V03/72V04/72V05/72V06 3.3V ASYNCHRONOUS FIFO
512 x 9, 1,024 x 9, 2,048 x 9, 4,096 x 9, 8,192 x 9 and 16,384 x 9
PIN CONFIGURATION
IDT72V01
IDT72V02
IDT72V03 IDT72V05
IDT72V04 IDT72V06
Commercial & Industrial
(1)
Commercial & Industrial
(1)
tA = 15, 25, 35 ns tA = 15, 25, 35 ns
Symbol Parameter Min. Max. Min. Max. Unit
ILI
(2)
Input Leakage Current (Any Input) –1 1 –1 1 µA
ILO
(3)
Output Leakage Current –10 10 –10 10 µA
VOH Output Logic “1” Voltage IOH = –2mA 2.4 — 2.4 — V
VOL Output Logic “0” Voltage IOL = 8mA — 0.4 — 0.4 V
ICC1
(4,5)
Active Power Supply Current — 60 — 75 mA
ICC2
(4,6)
Standby Current (R=W=RS=FL/RT=VIH)—5—5mA
NOTES:
1. Industrial temperature range product for the 25ns speed grade is available as a standard device. All other speed grades are available by special order.
2. Measurements with 0.4 ≤ VIN ≤ VCC.
3. R ≥ VIH, 0.4 ≤ VOUT ≤ VCC.
4. Tested with outputs open (IOUT = 0).
5. Tested at f = 20 MHz.
6. All Inputs = VCC - 0.2V or GND + 0.2V.
PLCC (J32-1, order code: J)
TOP VIEW
Symbol Rating Min. Typ. Max. Unit
VCC Supply Voltage 3.0 3.3 3. 6 V
GND Supply Voltage 0 0 0 V
VIH
(1)
Input High Voltage 2.0 — VCC+0.5 V
VIL
(2)
Input Low Voltage — — 0.8 V
TA Operating Temperature Commercial 0 — 70 °C
TA Operating Temperature Industrial –40 — 85 °C
Symbol Rating Com'l & Ind'l Unit
VTERM Terminal Voltage –0.5 to +7.0 V
with Respect to GND
TSTG Storage Temperature –55 to +125 °C
I
OUT DC Output Current –50 to +50 mA
NOTES:
1. For RT/RS/XI input, VIH = 2.6V (commercial).
For RT/RS/XI input, VIH = 2.8V (military).
2. 1.5V undershoots are allowed for 10ns once per cycle.
D
2
5
D
1
6
D
0
7
XI
8
FF
9
Q
0
10
Q
1
11
NC 12
Q
2
13
D
6
D
7
NC
FL/RT
RS
EF
XO/HF
Q
7
Q
6
29
28
27
26
25
24
23
22
21
4
3 2
1
32 31 30
14 15 16 17 18 19 20
Q
3
Q
8
GND
NC
R
Q
4
Q
5
D
3
D
8
W
NC
V
CC
D
4
D
5
INDEX
3033 drw 02b
Symbol Parameter
(1)
Condition Max. Unit
CIN Input Capacitance VIN = 0V 8 pF
C
OUT Output Capacitance VOUT = 0V 8 pF
RECOMMENDED DC OPERATING
CONDITIONS
ABSOLUTE MAXIMUM RATINGS
NOTE:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
DC ELECTRICAL CHARACTERISTICS
(Commercial: VCC = 3.3V ± 0.3V, TA = 0°C to +70°C; Industrial: VCC = 3.3V ± 0.3V, TA = –40°C to +85°C)
NOTE:
1. Characterized values, not currently tested.
CAPACITANCE
(TA = +25°C, f = 1.0 MHz)