293
Power
Distribution
& Terminal
Blocks
Power Distribution &
Terminal Blocks
Section Contents Page
SSeelleeccttiioonn ttaabbllee ffoorr SSCCCCRR PPDDBBss && PPoowweerr
tteerrmmiinnaall bblloocckkss .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 229944
PPoowweerr ddiissttrriibbuuttiioonn bblloocckkss
Series PDBFS enclosed, with high SCCR . . . . . . . . . . . .295
Series PDB with high SCCR . . . . . . . . . . . . . . . . . . . . . 296
PPoowweerr tteerrmmiinnaall bblloocckkss
Series 163 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297-298
Series 11675 2- to 12-Pole quick-connect . . . . . . . . . . . 299
Series 11725 2- to 4-Pole quick-connect . . . . . . . . . . . . 299
Series 160, 162, 163 & 165 . . . . . . . . . . . . . . . . . . . . . . 299
SSeerriieess 116622,, 116633 && 116655 ppoowweerr ssttuudd tteerrmmiinnaall bblloocckkss .. .. .. 330
000
SSeerriieess 116600,, 116622,, 116633 && 116655 ppoowweerr sspplliicceerr bblloocckkss .. .. .. .. 330000
SSeerriieess 1144000022 BBaarrrriieerr tteerrmmiinnaall bblloocckkss .. .. .. .. .. .. .. .. .
. .. .. .. .. .. 330011
SSeerriieess 1144000044 DDeeaadd ffrroonntt tteerrmmiinnaall bblloocckk .. .. .. .. .. .. .. .. .. .. .. .. 330011
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
229944
Power Distribution & Terminal Blocks
Selection Table for SCCR Power Distribution Blocks and
Power Ter minal Blocks
Shor t-Circuit Current Rated Power Distribution
Blocks
Cooper Bussmann of fers three distinctly dif ferent styles of
short-circuit cur rent rated power distribution blocks (PDBs)
and power terminal blocks (PTBs) to ma tch different
application needs. The dif ferences are whether the power
distribution blocks are enclosed or not, and whether they are
UL1953 Listed PDBs or UL1059 Recognized PTBs, which
have different minimum spacing requirements. The table on
this page can assist in the selection of the right series for
your application requirements.
Why these are impor tant?
Assembly short-circuit cur rent ratings (SCCRs) are now
required in the 2008 NEC
®
and UL 508A Listed Industrial
Control Panels. Mar king the SCCR on Industrial Control
Panels (NEC
®
409.110), Industrial Machiner y Electrical
Panels (NEC
®
607.3(A)), and HVAC equipment (NEC®
440.4(B)) is now required by the National Electrical Code.
PDBs or PTBs not marked with a SCCR, typically are the
weakest link and may limit an assembly to no more than 10kA
SCCR. The PDBFS and PDB Series have increased spacing
required where used in feeder circuits in equipment listed to
UL508A (UL1059 PTBs must be evaluated for proper spac-
ings). Also, for building wiring systems, the PDBFS Series
and PDB Series power distribution blocks can be used to
meet the new 2008 NEC
®
requirements in section 376.56(B)
for PDBs in wireways.
Industrial Industrial
Control Control HVAC Wireways
Description Catalog High Spacing** Panels Panels UL NEC
®
Page UL
Enclosed
SCCR* 1” Air UL 508A UL 508A 1995 376.56(B)
2” Surface Branch Feeder (Requires
Circuit Circuit UL 1953)
Series PDBFS 295 UL 1953 Listed Yes
Yes Yes Yes Yes Yes Yes
Yes
Series PDB 296 UL 1953 Listed No*** Yes Yes Yes Yes Yes w/optional
cover
Selection Table
IP20 finger-safe under specific conditions, see datasheet 1149.
*When protected by proper fuse class with maximum ampere rating specified or less.
** See PDB Spacing Requirements for Equipment table below.
***Optional covers are available. Not IP20, but provide a safety benefit.
****No, except: Yes, if single pole units installed with proper spacings.
Spacing between Spacing between
live par ts of live par ts and
UL Standard opposite polarity grounded par ts
or enclosure
@600V
508A Feeder
Circuits
508A Branch
Circuits
1995 HVAC
Through air Over surface
@600V @600V
1
˝
2
˝
1
˝
3
8˝
1
2˝
1
2˝
3
8
˝
1
2
˝
1
2
˝
Note: Refer to Specific UL standards for complete spacing details.
PDB & PTB Minimum Spacing
Requirements for Equipment
Data Sheet: 1049
Series PDBFS
Series PDB
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
229955
Power
Distribution
& Terminal
Blocks
Power Distribution & Terminal Blocks
Series PDBFS of Power Distribution Blocks
Feature/Benefits
• Enclosed, safer
installation; IP20
finger-safe under specific
conditions
• High short-circuit current
ratings up to 200kA:
PDBs do not have to be
the weak link in achieving
high SCCR for an
industrial control panel
• Small footprint saves
panel space
• Listed to UL 1953 which has minimum spacing
requirements at 600V of at least 1” through air and 2” over
surface required for feeders in UL 508A Industrial Control
Panels
• For 2D CAD drawings visit www.cooperbussmann.com
Agency/Standards
• UL Listed 1953, Guide QPQS, File E256146
• CSA Certified, Class 6228-01, File 15364
• IEC 60947-7-1
• IEC 60529, IP20 (finger-safe) under specific wiring
conditions
Electrical
• 600Vac/dc (UL 1953), 690Vac/dc (IEC)
• IP20 finger-safe under specific conditions
• Short-circuit current ra tings up to 200kA, see ta ble
• Ampacities up to 760 amps
• Cu wire range 14 AWG to 500 kcmil or 2.5 to 240 mm
2
Mechanical
• DIN rail or panel mount; PDBFS330 & PDBFS504 panel
mount only
• Captive termina tion screws; screws do not get misplaced
• Wire ready: captive termination screws shipped bac ked out
to save time on conductor installations
• Sliding DIN rail latch for easy mounting
• Single pole, gang mountable for multiple pole applications
with interlocking dovetail accessory (optional)
• Flammability, UL 94V0
• Tin-plated Al connectors suita ble for Cu conductors
• Elongated hole for panel mounting; easier mounting with
grea ter flexibility in matching up with drilled panel holes
• Part 2A1279: Interloc king dovetail pin accessor y
One pin interlocks two units, two pins to interlock three units
• DIN rail end anchors required to prevent damage to block
when torquing
Data Sheet: 1049
Ter minal Copper Conductor Capability Short-Circuit Cur rent Ra ting Data
Line Load Configuration Conductors Max Fuse Class & Amp**
Catalog
Number Openings per Pole Line Load J T RK1 RK5
(All Single
Amps Wire Range Wire Range
AWG or AWG or LPJ JJS LPS-RK FRS-R
SCCR
Pole) Line Load kcmil kcmil JJN LPN-RK FRN-R
PDBFS204 175A
2/0 to 8 AWG 2/0 to 8 AWG
2/0 to 8 2/0 to 8 200 200 100 60 200kA
70 to 10 mm
2
70 to 10 mm
2
2/0 to 8 AWG 4 to 14 AWG
4 to 12 200 200 100 60 200kA
PDBFS220 175A
70 to 10 mm
2
25 to 2.5 mm
2
2/0 to 8
14
175 175 100 60 100kA
200 200 100 60 50kA
350kcmil to 6 AWG 350kcmil to 6 AWG
PDBFS303 310A
185 to 16 mm
2
185 to 16 mm
2
350 to 6 350 to 6 400 400 200 100 200kA
500kcmil to 6 AWG 2 to 14 AWG
2 to 6 400 400 200 100 200kA
PDBFS330 380A
240 to 16 mm
2
35 to 2.5 mm
2
500 to 6
8 to 14
200 200 100 30 50kA
175 175 100 30 100kA
300kcmil to 4 AWG 4 to 14 AWG
300 4 to 8 600 600 400 200 200kA
PDBFS377 570A
150 to 12 mm
2
25 to 2.5 mm
2
250 to 4
4 600 600 400 200 50kA
6 to 14 200 200 100 30 50kA
PDBFS500 620A
350kcmil to 4 AWG 350kcmil to 4 AWG
350 350 600 600 400 200 200kA
185 to 12 mm
2
185 to 12 mm
2
300 to 4 300 to 4 600 800* 600 200 100kA
500kcmil to 6 AWG 500kcmil to 6 AWG
500 500
600 800* 600 400 200kA
PDBFS504 760A
240 to 16 mm
2
240 to 16 mm
2
600 800* 600 600 100kA
400 to 6 400 to 6 600 600 400 200 100kA
Ampacities 75ºC per NEC
®
Table 310.16 and UL 508A Ta ble 28.1
*Class L 800A (KRP-C 800_SP) or less fuses suitable for this par ticular SCCR case.
** Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30, KTK-R-30) or less are suita ble for all SCCRs in this table.
Series PDBFS