NEW PRODUCT
Eatons Crouse-Hinds Business
XLC Explosionproof
Lighting Contactors
© 2014 Eaton Corporation
All Rights Reserved
Printed in USA
May 2014
Eatons Crouse-Hinds Business
1201 Wolf Street
Syracuse, NY 13208
(866) 764-5454
crouse.customerctr@cooperindustries.com
XLC Lighting Contactors
from Eaton’s Crouse-Hinds
Business provide effi cient use
of power, greater utilization
of daylight and automated
control in the most extreme
harsh and hazardous locations
while extending lighting
lifetime.
Applications:
Areas requiring safe and ef cient variable
lighting control
Areas with hazardous gas, vapors and dust
Indoor or outdoor locations in damp, wet,
dusty or corrosive environments
Features and Bene ts:
Variable lighting control utilizing manual on/off
or automatic settings
Photocell option provides maximum
utilization of sunlight for energy conservation
Modular lighting contactor design provides
exibility to add future power poles
Lighting contacts are electrically held for
superior performance
Power poles convert from NO to NC with a
simple 180° turn
Standard con guration includes:
EJB121208 enclosure with mounting plate,
hinges and breather/drain
Captive, triple lead, quick release, hex head
stainless steel bolts with spring-loaded action
Tap-in mounting feet offer simple and secure
installation and are easily replaceable
Special neoprene cover gasket provides a
watertight seal to meet NEMA requirements
Internal neutral and ground bar
Electrically held modular lighting contactor
Two ¾ ” NPT control conduit entries - one on
top and one on bottom
Twelve 1” NPT power conduit entries - six on
top and six on bottom
DSL nameplates are standard for all operator
positions and Lamacoid nameplates are
available upon request
Certifications and Compliances:
Class I, Divisions 1 & 2, Groups B, C, D
Class I, Zones 1 & 2
Class II, Division 1, Groups E, F, G
• Class II, Division 2, Groups F, G
Class III
NEMA 3, 7BCD, 9EFG
UL Standard: 1203
cUL to CSA Standard C22.2 No. 30
Ex d IIB + H
2
Standard Materials:
Body and cover – copper-free aluminum
Gasket – neoprene
Cover bolts – stainless steel
Hinges – stainless steel
Electrical Ratings*:
Voltage: 600V
Coil voltage: 120V
Amperage: 30A
Number of poles: 1-12 standard
Options:
Suffix
Terminal block** ................................... TB
Timer**................................................. TR
EV2IH20 photocell (120V) ................... PC1
EV2IH208 277 photocell (208-277V) ... PC2
Epoxy  nish (external) ........................S752
Epoxy  nish (internal and external) ....S753
Lamacoid nameplate ............................ LID
Heater .................................................. R11
Example of lighting
contactor within the
XLC solution
Photocells are shipped separate for  eld installation.
*Additional con gurations are available upon request. Please contact Customer Service for details.
**Timer and/or terminal block will require a larger enclosure (EJB181208).
All entries are plugged as standard.
© 2014 Eaton Corporation
All Rights Reserved
Printed in USA
5105-0514
May 2014
Eatons Crouse-Hinds Business
1201 Wolf Street
Syracuse, NY 13208
(866) 764-5454
crouse.customerctr@cooperindustries.com
Ordering Information:
Amps = 30A
Poles 120V Poles 120V
2
XLC30A2
8
XLC30A8
3
XLC30A3
9
XLC30A9
4
XLC30A4
10
XLC30A10
5
XLC30A5
11
XLC30A11
6
XLC30A6
12
XLC30A12
7
XLC30A7
Catalog Numbering Example:
XLC Lighting Contactor, 30A, 120V, 6 pole, HOA 3-position switch in position 1, no operator in position 2, red pilot light in position 3, green pilot light in
position 4, HOA DSL in position 1, no DSL in position 2, ON DSL in position 3, OFF DSL in position 4, epoxy  nish (external).
XLC 30 A 6 - SXAB - 39X0708 S752
Amperage
30
30A
60*
60A
100*
100A
Coil Voltage
A
120V
B
208V*
C
240V*
D
480V*
E
600V*
Number of Poles
28
3 9
4 10
5 11
6 12
7
Select One Operator Symbol for Each of the Four Positions
The first operator is in position 1, second operator in position 2, etc.
NOTE: If no operator is required, use the symbol X.
A
Pilot Light - Red (EMP009-J1)
B
Pilot Light - Green (EMP009-J3)
C
Pilot Light - Amber (EMP009-J6)
G
Single Pushbutton - Black (EMP019)
Q
2-Position Switch (EMP049)
S
3-Position Switch (EMP069)
X
No Operator
Select One Device Nameplate for Each of the Four Positions
The first nameplate is in position 1, second nameplate in position 2, etc.
NOTE: If no nameplate is required, use the symbol X.
05
Start (DSL05)
06
Stop (DSL06)
07
On (DSL07)
08
Off (DSL08)
29
Hand Auto (DSL29)
37
Start-Stop (DSL37)
39
Hand Off Auto (DSL39)
48
Off-On (DSL48)
X
No Operator
Options
TB
Terminal Block**
TR
Timer**
PC1
EV2IH Photocell (120V)
PC2
EV2IH208 277 Photocell (208-277V)
S752
Epoxy Finish (External)
S753
Epoxy Finish (Internal and External)
R11
Heater
LID
Lamacoid Nameplate
Photocells are shipped separate for  eld installation.
*Additional con gurations are available upon request. Please contact Customer Service for details.
**Timer and/or terminal block will require a larger enclosure (EJB181208).
Base Catalog Number Operators Nameplates Options