3E
790
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
3E
Explosion Protected
Terminal Boxes
Series GHG 744, 745, 746, 749
UL/cUL Listed
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zones 1 & 2, AEx de IIB + H
2,T6
Cl. II, Div. 1, Groups E, F, G (cUL)
ATEX Certified
IECEx
CEPEL Certified
Ex de IIC, T6, Zones 1 & 2
Ex de IIC, T6 Zones 21 & 22
IP66, NEMA 4X
GOST-R
GOST-K
Applications:
Explosion protected terminal boxes are used in a metallic conduit or
cable system for a marshalling cabinet between main circuits to the
control room and branch circuits into the field.
Junction boxes for intrinsically safe or increased safety
connections
Are designed for industrial areas such as chemical plants, oil and
gas refineries, paint and varnish manufacturing plants, gasoline
bulk loading terminals and finishing areas where nonmetallic,
weatherproof enclosures
Features:
Enclosures can be mounted on walls, conduits or strut systems
Connection terminals accessible from all sides
Snap-out brass plates for metallic entry and grounding continuity
Snap-out terminal rails
Clip-in grounding PE rail
Different sizes to accommodate any number of terminal
connections
Standard Materials:
Fiberglass-reinforced polyester housings
Enclosure gasket – silicone
Cover screws – stainless steel
Metal entry plates – brass
Conduit entries – zinc Myers hubs
Technical Data:
Suitable from 1 to 296 terminal blocks (2.5mm
2
)
Suitable for up to 90 –
3
/4" hubs (largest size)
Suitable for up to 72 –
3
/4" metallic hubs
Suitable for use as control panels
Ex-e boxes and brass flanges can be field drilled
Ordering Data:
Contact factory for catalog numbers and pricing.
Have the following information ready –
Number and size of terminals (Table 1)
Number, size and location of entries (Tables 2 and 3)
Required ground points (Table 4) Eaton's Crouse-Hinds will provide
you with an extended list
Certifications and Compliances:
UL/cUL Listed
Class I, Division 2, Groups A, B, C, D
Class I, Zones 1 and 2, (A)Ex de IIB+H
2, T6
Class II, Division 1, Groups E, F, G (cUL)
ATEX Certified
Ex de IIC, T6, Zones 1 and 2
Ex de IIC, T6, Zones 21 and 22
IP66, NEMA 4X
GOST-R and GOST-K
Dimensions
In Inches:
3E
791
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
Panel and Side Designation:
The sides of the enclosures are designated as W, X, Y and Z alphabetically in a clockwise rotation.
The narrow sides are always W and Y and the long sides are X and Z.
Table 1
Maximum Number of Built-in Terminals Supplied with Enclosure
Terminal cross section in mm
2
Type 2.5 4 6 10 16 25 35
Length of
terminal rail
GHG 744
39 33 33 33 17 13 (1) 230 mm
GHG 745
2 x 40 2 x 33 2 x 39 2 x 33 40 30 20 (2) 235 mm
GHG 746
2 x 94 2 x 78 2 x 78 2 x 35 2 x 45 2 x 34 2 x 32 (2) 510 mm
GHG 749
2 x 148 2 x 124 2 x 94 2 x 75 2 x 63 2 x 63 2 x 51 (2) 795 mm
*The shallow cover is standard for terminal boxes. The deep cover is used when mounting larger sized terminal (>95 mm
2
) or switches for 80 amps and larger.
Table 2
Flange Arrangement for Each Enclosure
Enclosure 744 745 746 749
Removable
Flanges
2 total
1 - top and bottom
4 total
1 per side
6 total
2 top and bottom
1 each side
8 total
3 top and bottom
1 each side
Covers*
Shallow Deep or shallow Deep or shallow Shallow
# of DIN rails
1 1 or 2 1, 2, or 4 1, 2, or 6
Table 3
Maximum Number of Glands Per Side
Type Side M12 M16 M20 M25 M32 M40 M50 M63
NPT equivalent
1
/2"
3
/4"1"1
1
/4"1
1
/2"2"
GHG 744
X/Z 60 36 26 18 10 7 4 3
GHG 745
X/Z 60 36 26 18 10 7 4 3
GHG 746
X/Z 120 72 52 36 20 14 8 6
GHG 749
X/Z 180 108 78 54 30 21 12 9
# of glands/flange†
46 25 20 11 8 4 3 2
# of Myers hubs/flange†
1096332
† If flanges are used, fewer glands can be installed. See Table 1 for flange arrangement.
Example: In the GHG 745 box a maximum of (10)
1
/2" Myers hubs can be installed on each brass flange plates.
Each side will take one brass flange for a total of (40)
1
/2" Myers hubs.
Series GHG 744, 745, 746, 749
UL/cUL Listed
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zones 1 & 2, AEx de IIB + H
2,T6
Cl. II, Div. 1, Groups E, F, G (cUL)
ATEX Certified
IECEx
CEPEL Certified
Ex de IIC, T6, Zones 1 & 2
Ex de IIC, T6 Zones 21 & 22
IP66, NEMA 4X
GOST-R
GOST-K
3E
Explosion Protected
Terminal Boxes
Dimensions
In Inches: