www.microsensorcorp.com V1.0 04/2021
MPM426WPC
Level Transmitter
Feature
High Reliability, Safe and Easy to Use
Short Circuit and Reverse Polarity
Protection
Automatic Production Line Ensures High
Quality and Stability
Stainless Steel 316L Housing and
Teon® Jacketed Cable
High Corrosion Resistance and
Hermetically-sealed Structure, IP68
Introduction
The MPM426WPC level transmitter is a fully welded,
submersible level measurement device. It uses a
piezoresistive OEM pressure sensor with proven
long-term stability and reliability, and a special digital
compensation circuit that are built into a stainless steel
housing. The integrated structure and standardized
output signal make it easy for the on-site use and
automatic control. The vented Teflon® jacketed cable
and the housing are hermetically sealed, which can be
used in the liquids that are compatible with the sensor
material for a long time. It is mainly applied for the
pressure measurement and control of multiple chemicals.
02
MPM426WPC
Level Transmitter
www.microsensorcorp.com V1.1 04/2021
Construction Material
Housing: stainless steel 316L
Diaphragm: stainless steel 316L
Cable: φ7.5mm Teon
®
Jacketed Cable
Outline Dimension
(Unit: mm)
Electrical Connection
Electrical
Connection
Wire Color
9V~28V DC 5V DC
+V BLACK BLACK
+OUT RED RED
GND WHITE WHITE
Casing GREEN GREEN
T+ BLUE
T- BROWN
Specication
Level range: 0mH
2
O~2mH
2
O/3.5mH
2
O/5mH
2
O/10mH
2
O
/20mH
2
O/35mH
2
O
Pressure Type: Gauge
Overload: 1.5FS
Power Supply: 9V~28V DC or 5V DC
Output Signal
: 0.5V~4.5V DC (3-wire), with
temperature signal
Accuracy
: ±1% FS( ≤ 3.5mH
2
O)
±0.5% FS(>3.5mH
2
O)
Total Error
: ±2% FS( ≤ 3.5mH
2
O, -20
~75
)
±1.5% FS (> 3.5mH
2
O, -20
~75
)
Long-term Stability: ≤ ±0.3%FS/Year
Working Temperature: -30
~ 80
Storage Temperature: -40
~ 100
Insulation Resistance: 100V@100MΩ
Load Resistance: ≥ 10kΩ
Protection Rating: IP68
Weight: about 260g (Including no cable), cable is about
94g/m
①:
The sensors that use 5VDC as power supply only
supports the voltage output, no temperature output
is available;
②:
Test at normal temperature (reference condition
20
±5
), non-linear;
③:
The accuracy includes non-linearity, repeatability
and hysteresis within the working temperature
range.
MPM426WPC Wiring Diagram (Voltage Output Signal)