P-DUKE Technology Co., Ltd.
www.pduke.com
2023.12.28
Page 1
Medical
Automation
Datacom
IPC
Industry
Measurement
Telecom
Automobile
Boat
Charger
PV
Railway
PART NUMBER STRUCTURE
MAD180
U
S
12
A
-
M
Series Name
Universal
Output
Output
Protection
Package
Input
Quantity
Voltage
Type
Options
(VAC)
(VDC)
85~264
Single
12:
12V
A:
CLASS I
:
Open type
15:
15V
B:
CLASS II
E1:
Enclosed type
18:
18V
D1:
Din rail type
24:
24V
28:
28V
36:
36V
48:
48V
53:
53V
MAD180
Series
P-DUKE Technology Co., Ltd.
www.pduke.com
2023.12.28
Page 2
TECHNICAL SPECIFICATION All specifications are typical at 230VAC input, full load and 25℃ unless otherwise noted
Model
Number
Input Range
Output
Voltage
Output Current
Input Power
@ No Load
Efficiency
Maximum
Capacitor Load
Natural
Convection
Forced Air Cooling
With 10 CFM
VAC
VDC
A
A
W
%
μF
MAD180US12A-M
85 ~ 264
12
12.5
15
0.15
92
10000
MAD180US15A-M
85 ~ 264
15
10
12
0.15
92
6800
MAD180US18A-M
85 ~ 264
18
8.34
10
0.15
92
4700
MAD180US24A-M
85 ~ 264
24
6.25
7.5
0.15
94
2700
MAD180US28A-M
85 ~ 264
28
5.36
6.43
0.15
93
1800
MAD180US36A-M
85 ~ 264
36
4.17
5
0.15
93
1200
MAD180US48A-M
85 ~ 264
48
3.13
3.75
0.15
93
680
MAD180US53A-M
85 ~ 264
53
2.83
3.40
0.15
93
560
INPUT SPECIFICATIONS
Parameter
Conditions
Min.
Typ.
Max.
Unit
Operating input voltage range
AC input
DC input
85
120
264
370
VAC
VDC
Input frequency
AC input
47
63
Hz
Input current
100VAC and Full Load
240VAC and Full Load
3
1.5
A
No load input power
230VAC
0.15
Watts
Leakage current
264VAC
100
μA
Power factor
0.95
Start up time
1500
ms
Rise time
15
ms
Hold up time
115VAC and 150W
10
ms
Input inrush current
230VAC
100
A
Input protection
Internal fuse
T4.0A/250VAC
OUTPUT SPECIFICATIONS
Parameter
Conditions
Min.
Typ.
Max.
Unit
Output power
Forced air cooling with 10CFM
180
Watts
Natural convection
150
Output peak power
Peak power
Peak power time
Peak power duty
Average operation power ( % of Full Load)
5
20
55
220
Watts
s
%
%
Initial set voltage accuracy
230VAC and Full Load
-1.0
+1.0
%
Line regulation
Low Line to High Line at Full Load
-0.2
+0.2
%
Load regulation
No Load to Full Load
10% Load to 90% Load
-0.5
-0.4
+0.5
+0.4
%
Voltage adjustability
-8
+8
%
Minimum load
0
%
Ripple and noise
Measured by 20MHz bandwidth
With a 1μF/25V 1206 X7R MLCC
12Vout, 15Vout, 18Vout
120
mVp
With a 1μF/50V 1206 X7R MLCC
24Vout, 28Vout, 36Vout
120
mVp
With a 0.1μF/100V 1206 X7R MLCC
48Vout, 53Vout
250
mVp
Temperature coefficient
-0.02
+0.02
%/
Transient response
Load step from 100 ~ 75% change at 2.5A/μs
Peak deviation
Recovery time
3
600
% Vout
μs
Over voltage protection
% of Vout(nom); Latch mode
115
135
%
Over load protection
% of Iout rated; Hiccup mode
150
%
Short circuit protection
Continuous, automatics recovery