HighLight FL
High-Power Multi-Mode Fiber Lasers with
Beam Management
The HighLight
TM
FL series of industrial, multi-kilowatt ber lasers
provides a cost-eective solution for many common welding tasks.
These lasers feature Coherent’s unique multi-stage back reection
immunity system which enhances reliability and lifetime, and enables
safe processing of highly reective materials, including brass, copper,
and aluminum.
To maximize operational exibility, HighLight FL products are equipped
with either a Fiber-Fiber-Switch (FFS) or Fiber-Fiber-Coupler (FFC).
The FFS enables rapid switching of laser output between up to four
separate process bers, thus allowing time or energy sharing amongst
four workstations with a single laser. The FFC allows easy exchange of
process bers on site.
FEATURES & BENEFITS
Output power: 1,000 - 10,000 Watts
Fiber-Fiber-Switch (FFS) or
Fiber-Fiber-Coupler (FFC)
Excellent stability over the entire
power range (1% to 100%)
Inherently back reflection safe
Versatile production tool due to wide
range of beam qualities
Industry-leading closed loop power
control for high process consistency
Optimized power profile programming
tool for welding processes
CleanWeld
TM
technology to
optimize welding results
BENEFITS
Reliable and fast welding process
High welding seam and welded part quality
Minimized operating costs
APPLICATIONS
• Welding
• Cutting
HighLight FL Datasheet
SPECIFICATIONS HighLight FL1000 HighLight FL2000
Nominal Power (W) 1,000 2,000
Power Range (%) 1 - 100
Laser Beam Quality (BPP) at Collimator
(mm x mrad)
50 μm: ≤ 2.5; 100 μm: ≤ 4; 150 μm: ≤ 6
200 μm: ≤ 8; 300 μm: ≤ 12; 400 μm: ≤ 16
Power Stability (%) ± 1
Pulse Frequency Range (kHz) CW - 10
Wavelength (nm) 1070 ± 10
ELECTRICAL RATINGS
Voltage (VAC) 400/440/480 ± 10%
Max. Connected Load (kVA) 4.4 7.1
Max. Eective Power at Nominal Laser
Power at 400 V (kW)
4.2 6.9
Max. Current Consumption at 400 V (A) 6.1 9.9
Fuses Type NH (A) 16 32
COOLING
Recommended Cooling Capacity Laser (kW) 2.2 4.4
Recommended Cooling Capacity FFS/FFC
and QHB/QD (kW)
FFS2: 1.0; FFS4: 1.5; FFC: 1.0
Flow Rate Laser (l/min) 21
Flow Rate for FFS/FFC and QBH/QD (l/min) FFS2: 8.0; FFS4: 12.0; FFC: 6.0
Temperature Laser (°C) 25 ± 1
Temperature for FFS/FFC and QBH/QD (°C) 24 - 40
Max. Pressure Laser (MPa) 0.5
Max. Pressure for FFS/FFC and QBH/QD (MPa) 0.4
Typical Pressure Drop Laser (MPa) 0.25
FIBER DELIVERY SYSTEM
Interface QBH/QD
Diameter (µm) 50 - 400
Length (m) 10, 15, 20, 30, 35 (other lengths on request)
DIMENSIONS & WEIGHTS
Laser Dimension L x W x H (mm)
without signal tower
Midi: 794 x 1040 x 1067
Laser Weight (kg) FFC: < 400, FFS: < 450
ENVIRONMENTAL CONDITIONS
Ambient Temperature (°C) 5 - 40
Humidity (°C) Environmental conditions always below the dew point. Condensation to laser, QHB/QD and optics
must be avoided during the operation, storage and transport.
CUSTOMER INTERFACE
Digital Signals (V DC) 24
Power Control (V DC) 0 - 10 V
Gate Control (V DC) 24, rise/fall time < 30 µs
OPTIONS LASER
Field bus (Ethernet/IP, Pronet, Probus, Devicenet, Ethercat), Scanner control interface,
Multi station interface