1. Errata Summary
The table below lists all known errata for the EFR32MR21 and all unresolved errata of the EFR32MR21.
Table 1.1. Errata Overview
Designator Title/Problem Workaround
Exists
Exists on Revision:
B C
CUR_E304 Higher Than Expected EM2/EM3 Current No — X
GPIO_E302 Increased Leakage Current When EM4WU Pins Are Enabled and
the Pin State Is High
Yes X X
HFXO_E301 HFXO DISONDEMAND and FORCEEN Can Cause Device to
Hang
Yes X X
LFXO_E301 LFXO Minimum Load Capacitance Yes — X
RADIO_E308 Low Output Power for 20 dBm Power Amplifier at High Tempera-
ture
No — X
TIMER_E301 Continuous Overflow and Underflow Interrupts in Quadrature
Counting Mode
Yes X X
USART_E301 Possible Data Transmission on Wrong Edge in Synchronous
Mode
Yes X X
USART_E302 Additional SCLK Pulses Can Be Generated in USART Synchro-
nous Mode
Yes X X
USART_E304 PRS Transmit Unavailable in Synchronous Secondary Mode No X X
WDOG_E301 Clear Command is Lost Upon EM2 Entry Yes X X
EFR32MR21 Errata
Errata Summary
silabs.com | Building a more connected world. Rev. 0.2 | 2