Jul. 2023 IPM2-AA-23-0136-1
Renesas Solution Starter Kit (RSSK)
for RX23E-A
Accurately and eas ily evaluat e analog perform ance of RX23E-A
High-precision ADC integrated in RX23E-A evaluation board
This kit includes an RX23E-A-mounte d evaluatio n board with sensor measurement peripher al c ircuits .
By using it with software downloadable from the website, users can start evaluating analog features
right after unboxing. The kit helps users short en develo pme nt period and improve ti me-to-market.
Features
PC tool program
1. Peripheral circui ts necess ary for sensor measurement
Reference junction compensation circuit required for
thermocouple measurement
3-wire/4-wire resistance temperature detector (RTD)
measurement
Bridge-type sensor measurements, such as for strain
gauge
2. Easy ev aluation by GUI-based PC tool program
AFE parameters setting function
AD conversion result display function (time waveform,
histogram)
Digital filter frequency respo nse display
3. K-type thermocouple packaged
4. Sample programs for measurement available (*1)
Thermocouple measurement
RTD
Strain gauge measurement
5. Directly connect to E2 and E2-Lite emulators (*2)
6. Software development possible with only USB power
supply
7. Plug-in connector for analog input and miniature
thermocouple connector
8. RS485 and CAN-driver ICs on-board
*1 GUI and sample programs are released on web
*2 E2 and E2-Lite emulat ors are sold separa tely
E1 emulator can also be conne cted
PC tool program time waveform
RSSK for RX23E-A
PC tool program AFE parameter setting
PC tool program which is included in RSSK enable
starting evaluation w/o SW development.
GUI enables register setting of ΔΣADC and AFE
Measurement results and filter characteristics can
be checked graphically
Measurement results can be turned into the
histogram and CSV file
Jul. 2023 IPM2-AA-23-0136-1
RSSK Evaluation Results
The kit can be utilized to evaluate t he measureme nts
of thermocoup les, RTD, and strain gau ges, which
are typical sensors in industrial equip ment .
Our evaluatio n of K-ty pe thermocou ple s using the
RSSK shows that the measu red tempe rature error is
within ±0.6°C unde r environme nts betwe en -40°C
and 85°C and the ef fective resolu tion is 19.4 bit,
which means temperat ure dev iation is equivalent to
0.0015°C at rms value.
The measured tempe ratu re error, which is within the
sensor error, validates t he evaluat ion boa rd as a
reference design.
Our evaluation of load cell using the RSSK shows
that the measured weight error is within
±0.005%max.span and the effective resolution is
21.0 bit, which means weight deviation is equivalen t
to 4.8mg at rms value.
The measured weigh t error, which is within the
weight toleran ce, val idates t he evaluat ion boa rd as a
reference design.
Refer to applicat ion note s for more deta ils of each
sensor measurement evaluation.
RSSK Components
Temperature measurement result
Evaluation board
Thermocouple (Type-K)
PC tool program (*3)
User's Manual (*3)
Quick Start Guide (*3)
Circuit diagram(*3, included in UM )
Board diagram (*3, included in UM )
*3 Download from website
Related Application Note
Evaluation board
Thermocouple (Type K)
Document Number Title
R01AN4747EJ RX23E-A Group Temperatu re Measurement Example Using a Thermocouple
R01AN4788EJ RX23E-A Group Temperature Measurement Examples Using Resistance Temperature Detectors
R01AN4789EJ RX23E-A Group Weight Measurement Example Using a Load Cell
R01AN4799EJ RX23E-A Group Effec tive use of A FE and DSA D
R01AN5377EJ RX23E-A Group Analog Front End Typical Characteristics
R01AN5447EJ RX23E-A Group Force Sensor Measurement Example
-3
-2
-1
0
1
2
3
-50 -25 0 25 50 75 100 125 150
Error [deg C]
Temperature [deg C]
85
Room Temp
-40
Sensor error
Weight measurement result