POWR-GARD
®
Blocks & Holders
LSCR SERIES HIGH-SPEED FUSE BLOCKS
Dimensions mm (inches)
CHICAGO, ILLINOIS 60631
3RD ANGLE
PROJECTION
Littelfuse
®
REVISION
DRWG NO.
TITLE
DRW DATE
GRAMS/PIECE
FINISH GOOD WT
MATL SPEC FINISH
UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN
BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING
TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994
DENOTES CRITICAL CHARACTERISTICS.
DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE
DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION
OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT
AND TRACKING TO BE DEFINED IN
LITTELFUSE INSPECTION INSTRUCTIONS.
DENOTES CP DIMENSIONS, -MINIMUM CP VALUE
MUST BE WITHIN THE DIMENSIONAL LIMITATIONS
SHOWN ON DRAWING AND INITIALLY LOCATED TO
ALLOW FOR MAXIMUM TOOL LIFE.
CPK
CP
SHEET 1 OF 1
SCALE
A
OL-LSCR103
B
myork
9/2/2015
1000V 1200A FUSE HOLDER OUTLINE
NTS
REVISION
REV DATE DESCRIPTION
A
5/17/16
515753GCP - RELEASE PER EM2797 MRY
LSCR103
CHICAGO, ILLINOIS 60631
3RD ANGLE
PROJECTION
A
OL-LSCR000
Littelfuse
®
REVISION
DRWG NO.
TITLE
B
DRW DATE
GRAMS/PIECE
FINISH GOOD WT
MYORK
2/17/2015
MATL SPEC FINISH
UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN
BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING
TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994
DENOTES CRITICAL CHARACTERISTICS.
DENOTES CPK DIM
ENSIONS, -MINIMUM CPK VALUE
DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION
OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT
AND TRACKING TO BE DEFINED IN
LITTELFUSE INSPECTION INSTRUCTIONS.
DENOTES CP DIMENSIONS, -MINIMUM CP VALUE
MUST BE WITHIN THE DIMENSIONAL LIMITATIONS
SHOWN ON DRAWING AND INITIALLY LOCATED TO
ALLOW FOR MAXIMUM TOOL LIFE.
CPK
CP
SHEET 1 OF 1
SCALE
LSCR SERIES OUTLINE
NTS
REVISION
REV D
ATE DESCRIPTION
A
2/17/2015
514064GCP - RELEASE MRY
62.87
[2.48]
33.46
[1.32]
6.35
[0.25]
17.78
[0.70]
47.63
[1.88]
33.02
[1.30]
17.78
[0.70]
53.98
[2.13]
40.64
[1.60]
25.40
[1.00]
12.70
[0.50]
25.40
[1.00]
92.25
[3.63]
60.33
[2.38]
12.70
[0.50]
1/4-20" x 1.00"
USABLE LENGTH
3/8-16" x 1.00"
USABLE LENGTH
5.15 x 7.62 SLOT
[0.203 x 0.30]
5.15 x 7.62 SLOT
[0.203 x 0.30]
PART NUMBER
VOLTAGE RATING AMPERE RATING
SUGGESTED TORQUE
LSCR001 700 400A
6.8 N-m (61 IN-LBS)
LSCR002 700 800A
21.6 N-m (192 IN-LBS)
SPECIFICATIONS:
VOLTAGE RATING: SEE CHART
AMPERE RATING: SEE CHART
INTERRUPT RATING: 200kA AC/ 20kA DC
SUGGESTED TORQUE: SEE CHART
APPROVALS: UL RECOGNIZED (FILE NO. E14721)
CSA CERTIFIED (FILE NO.
73160)
DATA SHEET REVISION: 021115
LSCR001
LSCR002
6.35
[0.25]
LSCR001
CHICAGO, ILLINOIS 60631
3RD ANGLE
PROJECTION
Littelfuse
®
REVISION
DRWG NO.
TITLE
DRW DATE
GRAMS/PIECE
FINISH GOOD WT
MATL SPEC FINISH
UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN
BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING
TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994
DENOTES CRITICAL CHARACTERISTICS.
DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE
DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION
OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT
AND TRACKING TO BE DEFINED IN
LITTELFUSE INSPECTION INSTRUCTIONS.
DENOTES CP DIMENSIONS, -MINIMUM CP VALUE
MUST BE WITHIN THE DIMENSIONAL LIMITATIONS
SHOWN ON DRAWING AND INITIALLY LOCATED TO
ALLOW FOR MAXIMUM TOOL LIFE.
CPK
CP
SHEET 1 OF 1
SCALE
A
OL-LSCR101
B
myork
1/6/2015
1000V 400A FUSE HOLDER OUTLINE
NTS
REVISION
REV DATE DESCRIPTION
A
5/17/16
515753GCP - RELEASE PER EM2797 MRY
LSCR101
CHICAGO, ILLINOIS 60631
3RD ANGLE
PROJECTION
Littelfuse
®
REVISION
DRWG NO.
TITLE
DRW DATE
GRAMS/PIECE
FINISH GOOD WT
MATL SPEC FINISH
UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN
BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING
TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994
DENOTES CRITICAL CHARACTERISTICS.
DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE
DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION
OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT
AND TRACKING TO BE DEFINED IN
LITTELFUSE INSPECTION INSTRUCTIONS.
DENOTES CP DIMENSIONS, -MINIMUM CP VALUE
MUST BE WITHIN THE DIMENSIONAL LIMITATIONS
SHOWN ON DRAWING AND INITIALLY LOCATED TO
ALLOW FOR MAXIMUM TOOL LIFE.
CPK
CP
SHEET 1 OF 1
SCALE
A
OL-LSCR101
B
myork
1/6/2015
1000V 400A FUSE HOLDER OUTLINE
NTS
REVISION
REV DATE DESCRIPTION
A
5/17/16
515753GCP - RELEASE PER EM2797 MRY
LSCR002
CHICAGO, ILLINOIS 60631
3RD ANGLE
PROJECTION
A
OL-LSCR000
Littelfuse
®
REVISION
DRWG NO.
TITLE
B
DRW DATE
GRAMS/PIECE
FINISH GOOD WT
MYORK
2/17/2015
MATL SPEC FINISH
UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN
BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING
TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994
DENOTES CRITICAL CHARACTERISTICS.
DENOTES CPK DIM
ENSIONS, -MINIMUM CPK VALUE
DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION
OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT
AND TRACKING TO BE DEFINED IN
LITTELFUSE INSPECTION INSTRUCTIONS.
DENOTES CP DIMENSIONS, -MINIMUM CP VALUE
MUST BE WITHIN THE DIMENSIONAL LIMITATIONS
SHOWN ON DRAWING AND INITIALLY LOCATED TO
ALLOW FOR MAXIMUM TOOL LIFE.
CPK
CP
SHEET 1 OF 1
SCALE
LSCR SERIES OUTLINE
NTS
REVISION
REV D
ATE DESCRIPTION
A
2/17/2015
514064GCP - RELEASE MRY
62.87
[2.48]
33.46
[1.32]
6.35
[0.25]
17.78
[0.70]
47.63
[1.88]
33.02
[1.30]
17.78
[0.70]
53.98
[2.13]
40.64
[1.60]
25.40
[1.00]
12.70
[0.50]
25.40
[1.00]
92.25
[3.63]
60.33
[2.38]
12.70
[0.50]
1/4-20" x 1.00"
USABLE LENGTH
3/8-16" x 1.00"
USABLE LENGTH
5.15 x 7.62 SLOT
[0.203 x 0.30]
5.15 x 7.62 SLOT
[0.203 x 0.30]
PART NUMBER
VOLTAGE RATING AMPERE RATING
SUGGESTED TORQUE
LSCR001 700 400A
6.8 N-m (61 IN-LBS)
LSCR002 700 800A
21.6 N-m (192 IN-LBS)
SPECIFICATIONS:
VOLTAGE RATING: SEE CHART
AMPERE RATING: SEE CHART
INTERRUPT RATING: 200kA AC/ 20kA DC
SUGGESTED TORQUE: SEE CHART
APPROVALS: UL RECOGNIZED (FILE NO. E14721)
CSA CERTIFIED (FILE NO. 73160)
DATA SHEET REVISION: 021115
LSCR001
LSCR002
6.35
[0.25]
LSCR102
CHICAGO, ILLINOIS 60631
3RD ANGLE
PROJECTION
Littelfuse
®
REVISION
DRWG NO.
TITLE
DRW DATE
GRAMS/PIECE
FINISH GOOD WT
MATL SPEC FINISH
UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN
BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING
TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994
DENOTES CRITICAL CHARACTERISTICS.
DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE
DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION
OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT
AND TRACKING TO BE DEFINED IN
LITTELFUSE INSPECTION INSTRUCTIONS.
DENOTES CP DIMENSIONS, -MINIMUM CP VALUE
MUST BE WITHIN THE DIMENSIONAL LIMITATIONS
SHOWN ON DRAWING AND INITIALLY LOCATED TO
ALLOW FOR MAXIMUM TOOL LIFE.
CPK
CP
SHEET 1 OF 1
SCALE
A
OL-LSCR102
B
myork
9/2/2015
1000V 800A FUSE HOLDER OUTLINE
NTS
REVISION
REV DATE DESCRIPTION
A
5/17/16
515753GCP - RELEASE PER EM2797 MRY
Littelfuse.com/LSCR
© 2023 Littelfuse, Inc.
Rev: 032923
2 of 4