Data Sheet
SENCITY® OMNI-M Antenna
1399.17.0310
Document: DOC-0001149160 Rev A / date of publication: 13.06.2022 / uncontrolled copy
Page 1/3
Description
2-Port Antenna for Cellular.
Supports 2x2 Cellular MIMO for 3G, 4G and 5G.
Rugged design, meets EN 60068 Standard.
Single hole mount on cabinet or roof.
Product Configuration
Technical Data
Electrical Data
Band 1
Band 2
Band 3
Band 4
Band Name Cellular 1-2
Cellular 1-2
Cellular 1-2
Cellular 1-2
Frequency (MHz) 617 - 960
1350 - 2700
3300 - 4200
4900 - 7125
VSWR 1.9
2
1.7
1.7
Impedance (Ohm) 50
50
50
50
Gain (dBi) 2
5
6
6
Composite power max (W) 80
80
80
80
Ambient temperature (°C) 25
25
25
25
Port Isolation (dB) 9
20
20
20
Ports
Port 1
Port 2
Port name Cellular 1-2
Cellular 1-2
Connector N, jack (female)
N, jack (female)
Cable Type ENVIROFLEX_316_D
ENVIROFLEX_316_D
Polarization vertical
vertical
DC grounded Yes
Yes
Connections
Band 1
Band 2 Band 3 Band 4
Port 1 X
X X X
Port 2 X
X X X
Data Sheet
SENCITY® OMNI-M Antenna
1399.17.0310
Document: DOC-0001149160 Rev A / date of publication: 13.06.2022 / uncontrolled copy
Page 2/3
General Data
Indicated VSWR values and gain are valid for installations on metallic surfaces of 500x500 mm.
Please refer to the outline drawing to read the cable pigtail length of each port.
This Antenna is compliant with the Radio Equipment Directive 2014/53/EU
ETSI EN 303 413 V.1.1.1 (2017-06)
Mechanical Data
Dimensions (mm) 211.5 x 62.5 (Diameter x Height)
Weight (kg) 1.2
Corrosion: Low corrosion design according to MIL-F-14072(E), 96 hours Salt Spray test.
Mounting: Shall be installed in longitudinal position to the wind/driving direction.
Suitable for installation on vehicles with a maximum speed of 160 km/hr.
Environmental Data
Environmental conditions outdoor
Operation temperature (°C) -40 to 85
Storage temperature (°C) -55 to 85
Transport temperature (°C) -40 to 85
IP rating IP69
Solar radiation UL 746C, F1
2011/65/EU (RoHS - including
2015/863 and 2017/2102)
compliant acc. Annex III
Lead-free soldered yes
WEEE 2012/19/EU no special marking needed
ELV 2000/53/EC compliant
REACH 1907/2006/EC compliant
Environmental tests: EN 60068
EN 60068-2-1 Cold temperature test Ad, -55°C, 16h
EN 60068-2-2 Dry heat test Bd +85°C, 16h
EN 60068-2-30 Damp heat cyclic test Db, +25/55°C, 2 cycles
EN 60068-2-11 Salt Mist test Ka, 96h
EN 61373 § 9 Mechanical Vibration test, Cat. 2
EN 61373 § 10 Mechanical shock test, Cat. 2
EN 60529 Ingress protection test, IP69
Material Data
Radome colour RAL 7044 (light grey)
Radome material PC (Polycarbonate)
Back plate/base plate material Aluminum