1
Please scan the QR code for more
detailed product information.
www.qlight.com
Explosion Proof Warning Light/ Signal Light and
Electric Horn Combinations
SESA/ SESAS/ SESAL/ SESALR
1. During wiring or maintenance, please completely turn o-• the Power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
    ratings indicated for each product. (Failure to follow these instructions may cause a ¿re to the product, electric shock, physical injury,
    malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point.
   (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device.
   (Failure to follow this may cause damage to property, ¿re, electric shock and loss of life.)
Precaution for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
Safety Precautions for Explosion Proof Products
Please follow the instruction below to ensure safe and correct use of explosion proof products.
1. Explosion proof products should be managed according to explosion proof regulations. Do not disassemble, assemble, alter or repair
the product arbitrarily.
2. The temperature rating of the product is the temperature the product will experience at the applied rated voltage and ambient
temperature indicated.
3. Use cable glands that satisfy the product’s explosion proof grade and temperature grade.
4. Unused cable entries must be ¿lled with material that meets the explosion proof grade and temperature rating.
5. Before installing the product, please make sure all cautions indicated on the labels, packaging, and operation manual of the product
are fully understood.
6. Installation, maintenance and repair of the product must be performed by experts in the explosion proof ¿eld, or persons who have
received relevant training.
7. For safety, the product should be installed and operated in environments that avoid high temperature and high pressure.
8. Please follow general safety precautions and avoid installing the product in locations that may generate excessive heat.
9. When installing the product in places where chemicals are located, please make sure that the environment does not have two or more
    incompatible chemicals mixed. For safety, please read the instruction manual carefully and be mindful of the chemical compositions
where the product is used.
10. This product requires grounding.
11. Please note that special conditions shall be applied if the sign “X” is placed after the certi¿cate number.
      1) For safe use, regular overpressure test must be carried out in accord��ance with EN 60079-1, clause 15.2.3.
2) For safe use, tempered glass must be protected from strong impact
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn��� o-• the Power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s speci¿cation.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, ¿re, and electric shock.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
HORN
66
5540
118dB
HORN
66
5540
118dB
Ex
6040
2
Model number
SESA
SESAL
SESALR
SESAS
Range of
operating voltage
DC 12V or 24V
AC 110V or 220V
Ex mark
IECEX - Ex db IIC T6 Gb
AT��EX - II2G Ex db IIC T6 Gb
KCs - Ex d IIC T6 IP66
Ex tD A21 T85°C IP66
Ex d IIB+H2 IP66 T6
NEPSI - Ex d IIC T6 Gb
Ex tD A21 IP66 T80°C
CCC - Ex d IIC T6 Gb
Ambient operating
temperature
-40°C ≤ Ta ≤ 55°C(KCs)
-40°C ≤ Ta ≤ 60°C
Explosion proof
Zone
Zone1, Zone2, Zone21, Zone22
Protection rating
IP66
Model
number
Voltage Current
Bulb speci¿cations
Sound pattern and volume
Certi¿cate
Weight
Color
Volts/
Watts
Con¿guration
Part#
SESA
DC12V 3.755A
12V15W G23 15S 17
• WS-5 Warning sounds
: Max.118dB
• WP-5 Special warning sounds
: Max.118dB
• WM-5 Melodies : Max.118dB
• WA-5 Alarms: Max.116dB
• WV-5 Customizable sounds
: Max.113dB
8.57kg
R-Red
A-Amber
G-Green
B-Blue
DC24V 1.788A 24V15W G23 15S 18
AC110V 0.422A 12V15W G23 15S 17
9.27kg
AC220V 0.211A 12V15W G23 15S 17
SESAS
DC12V 2.933A
200V
-550V
EUB0641
-1A(G)
U type
48
8.45kg
DC24V 1.411A
AC110V 0.360A
8.86kg
AC220V 0.220A
Model
number
Voltage Current Sound pattern and volume
Certi¿cate
Weight
Color
SESAL
DC12V 2.511A
• WS-5 Warning sounds
: Max.118dB
• WP-5 Special warning sounds
: Max.118dB
• WM-5 Melodies : Max.118dB
• WA-5 Alarms: Max.116dB
• WV-5 Customizable sounds
: Max.113dB
8.42kg
R-Red
A-Amber
G-Green
B-Blue
DC24V 1.222A
AC110V 0.286A
9.02kg
AC220V 0.143 A
SESALR
DC12V 2.633A
8.31kg
DC24V 1.288A
AC110V 0.308A
7.92kg
AC220V 0.154A
Product Specications
Zone
de¿nitions(Gas)
Zone 1
High risk gas/vap���our
Zone 2
Medium risk gas/vapour
Group
de¿nitions(Gas)
GROUP II A
Acetone, Petrol, Methanol, Propane, Toluene
GROUP II B
Ethylene, City gas
GROUP II C
Hydrogen, Acetylene, Carbon sulphide
Maximum
surface
temperature
of electrical
equipment
T1
450
°C
T2
300°C
T3
200°C
T4
135
°C
T5
100
°C
T6
85
°C
Zone
de¿nitions(Dust)
Zone 21
High risk powder/dust
Zone 22
Medium risk powder/dust
Group
de¿nitions(Dust)
GROUP II A
Ignitible ¿bers/yings(mzore than 0.5mm)
GROUP II B
Non-conductive dusts
GROUP II C
Conductive dusts
Explosion Proof Specications
General Product Specication
Ordering Specications
SESAS
-
WS
-
220
-
R
[Model number]
[Sound]
[Voltage] [Color]
| | | |
• SESA
• SESAS
• SESAL
• SESALR
• WS-Warning sounds
• WP-Special warning sounds
• WM-Melodies
• WA-Alarms
• WV-Customizable sounds
• 12-DC12V
• 24-DC24V
• 110-AC110V
• 220-AC220V
R-Red
A-Amber
G-Green
B-Blue