PB 1
Explosion Proof LED Work Light
QLEX-SLM series
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
1. During wiring or maintenance, please completely turn o-• the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
    ratings indicated for each product. (Failure to follow these instructions may cause a ¿re to the product, electric shock, physical inju��ry,
    malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point.
   (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
5.
When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device.
   (Failure to follow this may cause damage to property, ¿re, electric shock and lo��ss of life.)
Precaution for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
Safety Precautions for Explosion Proof Products
Please follow the instruction below to ensure safe and correct use of explosion proof products.
1. Explosion proof products should be managed according to explosion-proof regulations. Do not disassemble, assemble, alter or repair
the product arbitrarily.
2.
The temperature rating of the product is the temperature the product will experience at the applied rated voltage and ambient
temperature indicated.
3. Use cable glands that satisfy the product’s explosion proof grade and temperature grade.
4. Unused cable entries must be ¿lled with material that meets the explosion proof grade and temperature rating.
5. Before installing the product, please make sure all cautions indicated on the labels, packaging, and operation manual of the product are
fully understood.
6. Installati��on, maintenance and repair of the product must be performed by experts in the explosion proof ¿eld, or persons who have
received relevant training.
7. For safety, the product should be installe���d and operated in environments that avoid high temperature and high pressure.
8. Please follow general safety precautions and avoid installing the product in locations that may generate excessive heat.
9. When installing the product in places where chemicals are located, please make sure that the environment does not have two or more
    incompatible chemicals mixed. For safety, please read the instruction manual carefully and be mindful of the chemical compositions
where the product is used.
10. Static electricity may be generated by physical contact due to the surface characteristics of this product so please use a wet towel
or anti-static cleaner to remove the foreign substances on the product.
11. Please be careful of static electricity during product installation.
Please eliminate static electricity by using static eliminator or handle the product with anti-static globes.
12. Be cautious of generating static electricity when installing the product. To avoid static electricity , use static-protective accessories or
Where anti-static gloves when handling the product.
13. Please note that special conditions shall be applied if the sign “X” is placed after the certi¿cate number.   
14. For safe use, regular overpres���sure test must be carried out in accordance with EN 60079-1, clause 15.2.3.    
15. For safe use, tempered glass must be protected from strong impact
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn o-• the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s speci¿cation.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, ¿re, and electric shock.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunctionof the product
that would void the warranty.
Please scan the QR code
for more
detailed product information.
www.qlight.com
67
66
6040
Ex
2 3
Explosion Proof Specications
Optics Specications/ General Product Specication
Product Specications
Model number
QLEX-SLM-250
QLEX-SLM-650
Range for
operating voltage
DC24V
AC220V
Ex mark
IECEx - Ex db II C T6 Gb
ATEX - ll 2 G Ex db llC T6 Gb
KCs - Ex d llC T6
(Except QLEX-SLM-250-220)
NEPSI - Ex d llC T6 Gb
(Only : QLEX-SLM-250-24)
Ambient operating
temperature
250 : –40°C ≤ Tamb ≤ +60°C
650 AC : –40°C ≤ Tamb ≤ +55°C
650 DC :–40°C ≤ Tamb ≤ +60°C
Explosion proof
Group / Zone
Zone1, Zone2
Protection rating
IP66/ IP67
Zone
de¿nitions(Gas)
Zone 1 High risk gas/vapour
Zone 2
Medium risk gas/vapour
Group
de¿nitions(Gas)
GROUP II A
Acetone, Petrol, Methanol, Propane, Toluene
GROUP II B Ethylene, City gas
GROUP II C Hydrogen, Acetylene, Carbon sulphide
Maximum surface
temperature of
electrical
equipment
T1 450°C
T2 300°C
T3 200°C
T4 135°C
T5 100°C
T6 85°C
Zone
de¿nitions(Dust)
Zone 21 High risk powder/dust
Zone 22 Medium risk powder/dust
Group
de¿nitions(Dust)
GROUP III A Ignitible ¿bers/yings(more than 0.5mm)
GROUP III B Non-conductive dusts
GROUP III C Conductive dusts
General Product Speci¿cation
Model number
QLEX-SLM-250 QLEX-SLM-650
Rated voltage
DC24V AC220V DC24V AC220V
Range for operation voltage
DC 21.6V-26.4V AC198V-242V DC 21.6V-26.5V AC 198V-242V
Power consumption
8.6W 9.0W 20.0W 23.0W
Insulation resistance
Min. 100M
(500V DC mega ohm meter)
Withstanding voltage
DC : 500VAC, 60Hz, 1minute / AC : 1,500VAC, 60Hz, 1minute
Protection rating
IP66/ 67
Materials
Side cover : Al, Lens : PC, Bracket : Al
Certi¿cate
Weight(approx.)
0.50Kg 0.93Kg
Optics Speci¿cations
Model number QLEX-SLM-250 QLEX-SLM-650
Lens color Translucent
Light color (Standard) Cooldaylight
Color temperature
(Standard)
6,000-7,000K
Luminous ux -
Illumination(at 1m) 240Lux 530Lux
QLEX-SLM - 250 - 24
[Model number] [Length] [Voltage]
| | |
• QLEX-SLM • 250-250mm
• 650-650mm
• 24-DC24V
• 220-AC220V
Ordering Specications