1. Errata Summary
Table 1.1. Errata Status Summary
Errata # Designator Title/Problem Workaround
Exists
Affected
Revision
Fixed
Revision
1 XOSC_E101 Crystal Mode in External Oscillator Not Available No A B
2 RST_E101 VREF/P0.0 Not Retained through Power-On Reset No A B
3 TIMER_E101 Timer 3/4 Chaining Mode in Suspend Yes A B
4 CLU_E101 CLU Wake-Up Sources are Level Triggered No A B
5 I2CSLAVE_E101 I2CSLAVE0 Cannot Distinguish Between Multiple Ad-
dresses
No A B
6 PKG_E101 Top Marking Right Justified No A, QFP32
devices with
1531 date
code
A, all devices
with other
date codes
7 PKG_E102 Devices Marked as G Grade No A, devices
with 1540
and 1602
date codes
A, all devices
with other
date codes
8 TEST_E101 Devices Tested to 85 °C No A, devices
with date
code 1530,
1531, or
1532
A, all devices
with other
date codes
Table 1.2. Errata History Overview
Designator Title/Problem Exists on:
Rev A Rev B
CLU_E101 CLU Wake-Up Sources are Level Triggered X —
I2CSLAVE_E101 I2CSLAVE0 Cannot Distinguish Between Multiple Addresses X —
PKG_E101 Top Marking Right Justified QFP32 devices with
1531 date code
—
PKG_E102 Devices Marked as G Grade A, devices with 1540
and 1602 date codes
—
RST_E101 VREF/P0.0 Not Retained through Power-On Reset X —
TEST_E101 Devices Tested to 85 °C A, devices with date
code 1530, 1531, or
1532
—
TIMER_E101 Timer 3/4 Chaining Mode in Suspend X —
WDT_E101 Restrictions on Watchdog Timer Refresh Interval X X
XOSC_E101 Crystal Mode in External Oscillator Not Available X —
EFM8LB1 Errata
Errata Summary
silabs.com | Smart. Connected. Energy-friendly. Rev. 0.2 | 1