1. Errata Summary
The table below lists all known errata for the EFR32FG23 and all unresolved errata in revision B of the EFR32FG23.
Table 1.1. Errata Overview
Designator Title/Problem Workaround
Exists
Exists on Revision:
A B
CUR_E302 Extra EM1 Current if FPU is Disabled Yes X X
DCDC_E302 DCDC Interrupts Block EM2/3 Entry or Cause Unexpected Wake-
up
Yes X X
EUSART_E301 PRS Transmit Unavailable in Synchronous Secondary Mode No X —
EMU_E305 DC-DC Refresh Time Delay Yes X X
I2C_E303 I2C Fails to Indicate New Incoming Data Yes X —
IADC_E305 FIFO Cannot Detect Eighth Entry Yes X X
RADIO_E306 Improper TX and RX Operation at High Temperature Yes X X
USART_E301 Possible Data Transmission on Wrong Edge in Synchronous
Mode
Yes X —
USART_E302 Additional SCLK Pulses Can Be Generated in USART Synchro-
nous Mode
Yes X —
USART_E304 PRS Transmit Unavailable in Synchronous Secondary Mode No X X
EFR32FG23 Errata
Errata Summary
silabs.com | Building a more connected world. Rev. 0.5 | 2