60W Single Output External Power
Industrial Grade
TE60 Family
TE60 Datasheet v0621 Copyright © 2021 SL Power Electronics Corp. All rights reserved. Page 1
Model Number Volts
Output
Current
Output
Power
Ripple &
Noise
1
Line
Regulation
Load
Regulation
Output
Connector
Output Cable
Input
Conguration
TE60A0551F01 5.0V 7.00A 35W 75mV pk-pk ±1% ±5%
6 pin Molex Type
2
2.5 x 5.5 x 9.5mm
Straight Barrel
Type, center
positive
#18AWG, See
mechanical
drawings for cable
length
Class I Desktop,
IEC60320 C14
Receptacle
TE60A0903F01 9.0V 6.00A 54W 90mV pk-pk ±1% ±5%
TE60A1203F01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5%
TE60A1503F01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5%
TE60A1803F01 18.0V 3.40A 60W 180mV pk-pk ±1% ±5%
TE60A2403F01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5%
TE60A4803F01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5%
TE60A0551N01 5.0V 7.00A 35W 75mV pk-pk ±1% ±5%
6 pin Molex Type
2
2.5 x 5.5 x 9.5mm
Straight Barrel
Type, center
positive
#18AWG, See
mechanical
drawings for cable
length
Class II Desktop,
IEC60320 C8
Receptacle
TE60A0903N01 9.0V 6.00A 54W 90mV pk-pk ±1% ±5%
TE60A1203N01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5%
TE60A1503N01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5%
TE60A1803N01 18.0V 3.40A 60W 180mV pk-pk ±1% ±5%
TE60A2403N01 24.0V 2.70A 60W 240mV pk-pk ±1%
±5%
TE60A4803N01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5%
TE60A0551Q01 5.0V 7.00A 60W 75mV pk-pk ±1% ±5%
6 pin Molex Type
2
2.5 x 5.5 x 9.5mm
Straight Barrel
Type, center
positive
#18AWG, See
mechanical
drawings for cable
length
Class II Desktop,
IEC60320 C18
Receptacle
TE60A0903Q01 9.0V 6.00A 54W 90mV pk-pk ±1% ±5%
TE60A1203Q01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5%
TE60A1503Q01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5%
TE60A1803Q01 18.0V 3.40A 60W 180mV pk-pk ±1% ±5%
TE60A2403Q01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5%
TE60A4803Q01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5%
Approved to EN/CSA/IEC/UL62368-1
E-Cap Life Of >8 Years
>900,000 Hours MTBF
3 Year Warranty
IP22 Rated Enclosure
Meets DoE Efficiency vel VI And EU CoC Tier 2
Requirements
No Load Input Power
Average Effic ncy
Up To 60W Of AC-DC Power
Universal Input 90-264Vac Input Range
Meets “Heavy Industrial” Levels Of EN61000
EMC Requirements
Meets EN55011/CISPR11, FCC Part 15.109 Class B
Conducted & Radiated Emissions, With 6Db Margin
FEATURES AND BENEFITS
MODEL SELECTION
Industrial
60W Single Output External Power
Industrial Grade
TE60 Family
TE60 Datasheet v0621 Copyright © 2021 SL Power Electronics Corp. All rights reserved. Page 2
AC Input
100-240Vac, ±10%, 47-63Hz, 1
Input Current
115Vac: 1.5A, 230Vac: 0.75A
Inrush Current
264Vac, cold start: will not exceed 40A
Input Fuses
F1, F2: 2A, 250Vac fuses (line & neutral lines)
provided on all models
Earth Leakage Current
Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC
Eciency
Meets US DoE Efficiency vel VI and EU CoC Tier 2
average efficiency vels
Common Mode Noise
High Frequency (100kHz-20MHz): <40mA pk-pk
No Load Input Power
<0.150W. Meets DoE Efficiency vel VI and EU CoC
Tier 2 Requirements
Output Voltage
See models chart on pg 1
Output Power
60W continuous See models chart for specific
voltage model ratings
Turn On Time
Less than 1 sec @115Vac, full load
Hold-up Time
20mS min., at full Load, 100Vac input
Ripple and Noise
See models chart on pg 1
Notes:
1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors. For 5V and 6V models, values listed are typical, 100V
pk-pk maximum
2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information
3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE60B1203F01)
4. All specifications a e typical at nominal input, full load, at 25°C ambient unless noted
Overvoltage Protection
130 to 150% of output voltage (max. 60V on
48V model), hiccup mode
Short Circuit Protection
Hiccup Mode, auto recovery
Overtemperature Protection
Will shutdown upon an over-temperature
condition, auto-recovery
Overload Protection
130 to 180% of rating, Hiccup Mode
INPUT OUTPUT
PROTECTION
EMI/EMC COMPLIANCE
Conducted Emissions
EN55032//EN55022/CISPR22 Class B, FCC Part
15.107, Class B: 6db margin typ, 115/230Vac
Radiated Emissions
EN55032/EN55022/CISPR22 Class B, FCC Part
15.109, Class B: 3db margin typ, 115/230Vac
Electro-Static Discharge
(ESD) Immunity on Power
ports
EN55024/IEC61000-4-2, Level 4: +/- 8kV
contact, +/- 15kV air, Criteria A
Radiated RF EM Fields
Susceptibility
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz,
80% AM at 1kHz
Electrical Fast Transients
(EFT) /Bursts
EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz
rep rate, 40A, Criteria A
Surges, Line to Line (Diff
Mode) and Line
to GND (CMN Mode)
EN55024/IEC61000-4-5, Level 4, +/-2kV DM,
+/-4kV CM, Criteria A
Conducted Disturbances
induced by RF
Fields
EN55022/IEC61000-4-6, 10Vrms Level 4, in
ISM and amateur radio bands between 0.15Mhz
and 80Mhz, 80% AM at 1KHz
Rated Power frequency
magnetic elds
EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60
Hz
Voltage Interruptions, Dips,
Sags &
Surges
EN55024/IECEN61000-4-11:
--100% dip for 20mS, Criteria A
--100% dip for 5000mS (250/300 cycles),
Criteria B
--60% dip for 100mS, Criteria B
--30% dip for 500mS, Criteria A
Harmonic Current Emissions
EN55011/EN61000-3-2, Class A
Flicker Test
EN61000-3-3
All specificationsare typical at nominal input, full load, at 25°C ambient unless noted