User Manual NanoFit Standby UPS
400VA/600VA/800VA
Inspection
The following items are inside the box:
UPS unit User manual
Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
re-pack the unit and return it to the place of purchase.
Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to
charge inside battery. For best result, charge the battery for 6 hours
prior to initial use.
Plug in Equipment
Battery Backup Outlets(3)
Connect computer and monitor to the "Battery Backup" outlets.
These outlets provide battery backup, EMI filtering, line
conditioning, and surge protection. Battery power is automatically
provided in case of power failure.
Surge-Protected Outlets(3)
Connect a printer, fax machine, or scanner to the “Surge-protected
ou
tlets. These outlets do not provide power during power failure.
CAUTION: NEVER connect a laser printer or scanner to the
battery backup sockets of UPS. The equipment may draw
significantly power to overload the UPS.
Turn On/Off the UPS
To turn on the UPS unit, press the power switch lightly. Then, the
LED or LCD will light up. To turn off the UPS unit, press the power
switch again. Then, display will shut off.
*Outlet type can be schuko,
UK or universal.
LED
Alarm
UPS Status
Green
Off
The mains is normal and
UPS is operated
normally.
Yellow
Sounding every
10 seconds
Power failure occurs and
UPS is on battery mode.
Yellow
Sounding every
second
Low battery
Green
Off
UPS is off.
Red
Continuously
sounding
UPS fault
LED on LED Off LED flashing
Operation Display
UPS
Mode
LCD
Description
UPS
Power on
When UPS is powered
on, it will enter this
mode for 4 seconds.
AC Mode
LCD information will be
displayed in the
following order when
LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
in AC
mode
icon will flash.
When overload occurs,
alarm will beep every
0.5 second.
Battery
Mode
When battery level is low,
icon will flash.
Alarm will beep every
10 seconds and LCD
information will be
displayed in the
following order when
LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
in battery
mode
icon will flash.
When overload occurs,
alarm will beep every
0.5 second.
NOTE: If backlight shuts off, you may activate it by touching the
screen.
Fault Code Table:
LCD
Solutions
Disconnect short-circuited
loads and restart the UPS
again.
Disconnect all output loads
and restart the UPS again.
Call for service immediately.
Please replace the battery.
Call for service immediately.
If fault alarm occurs, please call for service immediately.
1
LCD display or LED indicators
(Please check LED or LCD section
for the details)
2
Power switch
3
AC input
4
Battery backup &
Surge-protected outlets
5
Surge-protected outlets
6
USB port (option)
7
Modem/phone/network surge
protection
8
Coax surge protection (option)
9
USB charger port
INSTALLATION & OPERATION
PRODUCT OVERVIEW
LCD DISPLAY
LED Indicators
User Manual NanoFit Standby UPS
400VA/600VA/800VA
This UPS utilizes voltage that may be hazardous. Do not
attempt to disassemble the unit. The unit contains no user
replaceable parts. Only factory service personnel may
perform repairs.
This pluggable type A equipment with battery already installed
by the supplier is operator installable and may be operated by
laymen.
The mains socket outlet that supplies the UPS shall be installed
near the UPS and shall be easily accessible.
During the installation of this equipment it should be assured
that the sum of the leakage currents of the UPS and the
connected loads does not exceed 3.5mA.
Connection to any other type of receptacle other than a
two-pole, three-wire grounded receptacle may result in shock
hazard as well as violate local electrical codes.
In the event of an emergency, press the "OFF" button and
disconnect the power cord from the AC power supply to
properly disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS.
Do not place beverages or any other liquid-containing vessels
on or near the unit.
This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive
contaminants). Avoid installing the UPS in locations where
there is standing or running water, or excessive humidity.
Do not plug the UPS input into its own output.
Do not attach a power strip or surge suppressor to the UPS.
Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or
vacuum cleaners to UPS.
Do not dispose of batteries in a fire as they may explode.
Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell
battery.
MODEL
400
600
800
CAPACITY
400VA/
240W
600VA/
360W
800VA/
480W
Input Voltage
220/230/240 VAC
Input Voltage Range
180-270 VAC
Output Voltage
Regulation
± 10 % (Bat. mode)
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
Battery Type
12V/4Ah
12V/4.5Ah
12V/5Ah
Battery Number
1
1
1
Charging Time
8 hours recover to 90% capacity
Dimension (DxWxH)mm
305 x 158.5 x 95
Net Weight (kgs)
2.5
2.6
2.9
Humidity
0-90% RH @ 0-40°C non-condensing)
Noise Level
Less than 40dB
*Specifications are subject to change without notice.
A battery can present a risk of electrical shock and high short
circuit current. The following precautions should be observed
when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or
disconnecting batteries terminal.
6) Remove battery grounds during installation and maintenance
to reduce likelihood of shock.
Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required
precautions. Keep unauthorized personnel away from
batteries.
When replacing batteries, replace with the same number and
type of sealed lead-acid battery.
Do not open or mutilate the battery or batteries. Release
electrolyte is harmful to the skin and eyes. It may be toxic.
Attention, hazardous through electric shock. Also with dis-
connection of this unit from the mains, hazardous voltage still
may be accessible through supply from battery. The battery
supply should be therefore disconnected in the plus and minus
pole at the connectors of the battery when maintenance or
service work inside the UPS is necessary.
To reduce the risk of overheating the UPS, do not cover the
UPS' cooling vents and avoid exposing the unit to direct
sunlight or installing the unit near heat emitting appliances such
as space heater or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
WARNING: This is a category C2 UPS product. In a residential
environment, this product may cause radio interference, in
which case the user many be required to take additional
measures.
Problem
Possible Cause
Solutions
Nothing is
displayed on
the panel.
The UPS is not on.
Press the power switch
again to turn on the UPS.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Battery fault.
Replace the battery.
The UPS
always on
battery mode.
Power cord loose.
Re-plug the power cord.
The UPS
continuously
beeps.
Please check the fault
code for the details.
Please check the fault code
for the details.
Backup time
too short.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Overload.
Remove some unnecessary
loads. Before reconnecting
equipment, please verify
that the load matches the
UPS capability specified in
the specs.
Battery defect.
Replace the battery.
If any abnormal situations occur that are not listed above, please
call for service immediately.
SAFETY CAUTION
SAVE THESE INSTRUCTION-This manual contains important instructions that should be followed
during installation and maintenance of the UPS and batteries.
SPECIFICATIONS
TROUBLESHOOTING