thermoIMAGER TIM // Compact thermal imaging cameras
More Precision
17
approx. 426
approx. 271
142
166
166
Cooling Jacket Advanced – Extended versionCooling Jacket Advanced – Standard version
142
229
114
138
ø 88.90
R5
Cooling Jacket
Cooling Jacket and Cooling Jacket Advanced
Universal cooling housing for infrared cameras up to 315 °C
Ambient operating temperatures up to 315 °C
Also available with protection housing and cooling function up to 180 °C
Air/Water cooling with integrated air purging and optional protective windows
Modular design for easy fitting of different devices and lenses
Easy sensor removal on site due to quick-release chassis
Integration of additional components like TIM NetBox, USB Server Gigabit and Industrial
Process Interface (PIF) in the extended version
Model Cooling Jacket Cooling Jacket Advanced Standard Cooling Jacket Advanced Extended
Protection class IP65 IP65 IP65
Ambient temperature range up to 180 °C up to 315 °C
1)
up to 315 °C
1)
Relative humidity 10 to 95 %, non-condensing 10 to 95 %, non-condensing 10 to 95 %, non-condensing
Material (housing) V2A V2A V2A
Dimensions 237 mm x 117 mm x 138 mm 271 mm x 166 mm x 182 mm 426 mm x 166 mm x 182 mm
Weight 4.5 kg 5.7 kg 7.8 kg
Air purge collar
G1/4“ internal thread
G3/8“ external thread
G1/4“internal thread
G3/8“ external thread
G1/4“ internal thread
G3/8“ external thread
Cooling water fittings
G1/4“ internal thread
G3/8“ external thread
G1/4“ internal thread
G3/8“ external thread
G1/4“ internal thread
G3/8“ external thread
Cooling water pressure max. 15 bar (217 psi) max. 15 bar (217 psi) max. 15 bar (217 psi)
Scope of supply
Cooling Jacket, consisting
of housing and chassis
Cooling Jacket Advanced,
consisting of housing with
mounting angle, chassis
Assembly instructions
Cooling Jacket Advanced,
consisting of housing with
mounting angle, chassis
Mounting accessories for TIM NetBox
or USB Server Gigabit and Industry PIF
Assembly instructions
Focusing unit or front attachment
2)
Focusing unit or front attachment
2)
1)
Cable for up to 250 °C ambient temperature as well as cable cooling for up to 315 °C available.
2)
Must be ordered separately.
R54
R54
6,4
15
22
42
15
Ø6.4
R54
R54
6,4
15
22
42
15
Ø6.4
TM-MB-TIM adjustable mounting foot
TM-PH-TIM protection housing incl. mounting foot