UG522: Mandatory Crystal Adjustment for
EFR32ZG14/EFR32ZG23 Based Products
User's Guide
This document describes the mandatory adjustment of the system
crystal which must be performed on a product based on the
EFR32ZG14 and EFR32ZG23 devices.
The purpose of this document is to describe the required method to match the system
crystal of an EFR32ZG14- or EFR32ZG23-based products to the parasitic of that prod-
uct. The procedure is required to ensure that the crystal tolerances of the product are
within the specifications of the Z-Wave protocol.
KEY POINTS
• About Crystal Tolerances
•
How to Adjust the System Crystal
• Effects of the System Crystal's Production
Calibration
• Second Source Crystal Components
Audience:
The intended readers of this document are:
•
Product design engineers
• Production test engineers
• Z-Wave application programmers
Prerequisites:
The readers of this document are assumed to have knowledge of:
• The Z-Wave protocol
• Basic RF knowledge
• Basic RF measurement skills
Access to the bring-up software tool RailTest is required.
Knowledge and access to the following documents are essential:
• [1] UG523: Bring-Up/Test HW Development User's Guide
• [2] AN961: Bringing Up Custom Devices for the Mighty Gecko and Flex Gecko
Families
silabs.com | Building a more connected world. Copyright © 2021 by Silicon Laboratories Rev. 8