The Clarity
TM
110 test cable boasts steel torque crush
and overbend protection with abrasion resistance -
without compromising flexibility. The cable is ultra-stable
through 110 GHz with exceptionally low attenuation.
The design includes an ergonomic, stainless steel
protective barrel strain relief and a hex coupling nut.
Test and Measurement
Features:
• Broad Frequency Response
• Rugged & Durable
• Phase Stable Over Temperature
• Long Flex Life
Units
Armored Diameter: armor
in (mm) 0.19 (4.70)
Armored Diameter: strain relief
in (mm) 0.31 (8.00)
Minimum Bend Radius armored
in (mm) 1.0 (25.4)
Minimum Bend Radius max flex life
in (mm) 2.0 (50.8)
Crushing (armored version)
lbs/lin.in 200
Flex Life
>50000
Velocity of Propagation
% 70
Shielding Effectiveness
dB >100
Capacitance
pF/ft (pF/m) 29 (95)
VSWR Typical
1.40:1
VSWR Max
1.45:1
Phase Stability typical*
º +/- 2
Amplitude Stability typical*
dB +/- 0.075
Times Microwave Systems
358 Hall Avenue, Wallingford, CT 06492, USA
T 800. 867.2629 F 203. 949.8423
www.timesmicrowave.com
Op Temp
-67 to 257ºF
-55 to 125ºC
Impedance
50 Ohms
CENTER CONDUCTOR
Solid Silver Plate Copper
ROUND WIRE BRAID
Silver Plated Copper
INTERLAYER
Abrasion Resistant
PTFE
FEP
High Purity
SPRING
Stainless Steel
HELICALLY INTERLAYER
WIRE ROUND BRAID
Stainless Steel
OUTER BRAID
Abrasion Resistant PTFE
FEP JACKET
Frequency GHz dB/100 ft dB/100 m
110
500 1640
Attenuation @77ºF (+25ºC)
110
Specifications
*The assembly is terminated with a short circuit and bent 90 degrees
around the mandrel of 1-inch radius.
Attenuation (per 100ft) at any frequency:
1.0932*sqrt(f(MHz)) + 0.00125*f(MHz)
Ordering Guide
CLS110 - 10M 10M -10.00M
- Connector A Connector B - Length
M Meters
F Feet
CODE
Description
10M
1.0mm Male Connector
10F
1.0mm Female Connector
Assembled and tested assemblies
provide assured performance.
Global manufacturing
capability: US, and Asia.
Heritage—in the air and on the ground,
thousands of assemblies built over decades.
Amplitude Stability While in Motion
Phase Stability While in Motion
Our flex test method uses 4ft cables at 110GHz. The testing equipment calibration occurs every 8 hours. Email us at techquestions@timesmicro.com
to obtain a copy of the test procedure specifications and results.
4 ft assembly, 110 Ghz
4 ft assembly, 110 Ghz
-17
-18
-19
-20
-21
-22
-23
17136 25632
50
40
30
20
10
-10
-20
-30
0
17136
25632
Test and Measurement
Times Microwave Systems
358 Hall Avenue, Wallingford, CT 06492, USA
T 800. 867.2629 F 203. 949.8423
www.timesmicrowave.com