Test Report.
No. CANEC2119283108 Date: 26 Oct 2021 . Page 1 of 6.
TOLL MICROELECTRONIC INC.,LTD .
NO.101,PODIUM BUILDING A ,ZERO-ONE SQUARE,SOFTWARE PARK,NO.72 SECOND KEJI
ROAD,HIGH-TECH ZONE,XI’AN,SHAANXI
.
.
The following sample(s) was/were submitted and identified on behalf of the clients as : TMI3252S .
SGS Job No. :
CP21-055459 - SZ .
Client Ref. Info. : .
PLEASE SEE REMARK .
Model No. :.
TMI3252S.
Date of Sample Received : . 19 Oct 2021.
Testing Period :. 19 Oct 2021 - 26 Oct 2021 .
Test Requested : .
Selected test(s) as requested by client. .
Please refer to next page(s). .
Please refer to next page(s). .
Test Method :.
Test Results :.
Allie Chen.
Approved Signatory .
Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch.
Test Report.
No. CANEC2119283108 Date: 26 Oct 2021 . Page 2 of 6.
Test Results :.
Test Part Description : .
Specimen No..
SGS Sample ID.
Description.
SN1. CAN21-192831.006 “TMI3252S”.
Remarks :.
(1) 1 mg/kg = 1 ppm = 0.0001% .
(2) MDL = Method Detection Limit .
(3) ND = Not Detected ( < MDL ) .
(4) "-" = Not Regulated .
Halogen.
Test Method :.
With reference to EN 14582:2016, analysis was performed by IC. .
Test Item(s). Unit. MDL.
006.
Fluorine (F). mg/kg. 50 ND.
Chlorine (Cl). mg/kg. 50 ND.
Bromine (Br). mg/kg. 50 ND.
Iodine (I). mg/kg. 50 ND.