Key features
PAM4 for 400G/200G/100G/50G applications and NRZ/PAM2 for
100G/50G/10G and slower applications
80C10C 80 GHz optical bandwidth and low noise capability for
performance testing and signal characterization:
80C10C Option F1 provides 70 GHz full bandwidth and fully
integrated selectable reference receiver filtering, enabling
conformance testing at either 1310 nm or 1550 nm region for
25.781 Gb/s (100GBASE-ER4 and 100GBASE-LR4),
27.952 Gb/s (OTU-4), 39.813 Gb/s (OC-768/STM-256,
VSR-2000 G.693, 40G NRZ G.959.1), 41.25 Gb/s (40GBASE-
FR), 43.018 Gb/s (OTU3, VSR-2000 w/ FEC, 4x10G LAN PHY
OTU3), 44.5 Gb/s (OTU3), 53.125 GBd (PAM4 Ethernet 100G
per lane, TDECQ), and 57.8 GBd (64GFC) in a single module
80C10C Option F2 provides 55 GHz full bandwidth and fully
integrated selectable reference receiver filtering, enabling
conformance testing at either 1310 nm or 1550 nm for
27.952 Gb/s (OTU-4), 25.781 Gb/s (100GBASE-LR4 and
100GBASE-ER4)
80C10C Option F3 provides 80 GHz full bandwidth and fully
integrated selectable reference receiver filtering, enabling
conformance testing of 39.813 Gb/s (OC-768/STM-256,
VSR-2000 G.693, 40G NRZ G.959.1), 41.25 Gb/s (40GBASE-
FR), 43.018 Gb/s (OTU3, VSR-2000 w/ FEC, 4x10G LAN PHY
OTU3), 44.5 Gb/s (OTU3), 53.125 GBd (PAM4 Ethernet 100G
per lane, TDECQ), and 57.8 GBd (64GFC)
80C10C Clock Recovery for 25-44.5 Gb/s rates is supported
by the CR286A-HS or similar
5
(sold separately) and Option
CRTP and HSPR (electrical signal outputs to 44.5 Gb/s)
80C15 provides 32 GHz full bandwidth and fully integrated optical
reference receivers (ORR)
6
, enabling conformance testing of both
single and multi-mode conformance testing at 850,1310 and
1550 nm. The module includes bandwidth filters which support the
following rates: 25.781 Gb/s (100GBASE-SR4, Inifiniband EDR,
TDEC), 27.952 Gb/s (OTU-4), and 28.05 Gb/s (32G Fibre Channel)
80C15 Option CRTP provides a second, high-sensitivity
optical input to drive Clock Recovery Trigger Pickoff (CRTP)
electrical differential outputs for clock recovery functions or
error detection.
80C17 and 80C18 provide >30 GHz full bandwidth and fully
integrated optical reference receivers (ORR)
6
, enabling
conformance testing of both single and multi-mode conformance
testing at 850, 1310 and 1550 nm. The module includes bandwidth
filters which support the following rates: 25.781 Gb/s (100GBASE-
ER4, -LR4, -SR4, Inifiniband EDR); 26.5625 (PAM4 50G per lane),
TDECQ, TDEC (100GBASE-SR4), 27.952 Gb/s (OTU-4), and
28.05 Gb/s (32G Fibre Channel), and 53.125 GBd
7
PAM4/TDECQ.
80C17 and 80C18 Option CRTP provides an additional, high-
sensitivity optical input to drive Clock Recovery Trigger Pickoff
(CRTP) electrical differential outputs for clock recovery
functions or error detection up to 28.05 GBd.
80C20 and 80C21 provide up to 53 GHz of optical bandwidth and
lowest noise capability for performance. Used in conjunction with
the bandwidth enhancements feature of 80SJNB or 400G-M4
applications, the 80C20 and 80C21 provide reference receiver
filtering, enabling conformance testing at either 1310 nm or
1550 nm region for 25.781 Gb/s (100GBASE-ER4 and 100GBASE-
LR4), TDECQ, 26.56 Gb/s (OTU-4), 39.813 Gb/s (OC-768/
STM-256, VSR-2000 G.693, 40G NRZ G.959.1), 43.018 Gb/s
(OTU3, VSR-2000 w/ FEC, 4x10G LAN PHY OTU3), 44.5 Gb/s
(OTU3), and 53.125 GBd (PAM4 Ethernet 100G per lane, TDECQ)
in a single module
10 Gb/s Telecom and Datacom
Highly accurate ER calibrated (Extinction ratio) measurement
option for increased repeatability and transferability of the
measurement. ER Adjusted is also available (for any symbol rate)
80C14 - Low-noise, high optical sensitivity, broad wavelength
conformance testing for 10GbE, 40GbE (R4), 100GbE (X10) LAN,
WAN, FEC, 10G Fibre Channel, 16G Fibre Channel (14.025 Gb/s),
14G Infiniband FDR (14.06250 Gb/s)
80C08D and 80C12B (w/ Option 10G or 10GP) – low-noise, high
optical sensitivity, and broad wavelength conformance testing for
10 GbE, 40 GbE (R4), 100 GbE (X10) LAN, WAN, FEC, 10G fibre
channel, and 10 Gb/s telecom standards and FEC rates
80C11B 30 GHz optical bandwidth conformance testing and
characterization for 10 Gb/s telecom and datacom standards and
FEC rates
Clock Recovery solutions for 10 Gb/s applications
80C14 clock recovery for rates ≥8.5 Gb/s is supported by
CR175A (Sold separately)
80C08D and 80C11B Integrated Clock Recovery supports all
current 10 Gb/s standards or user-defined rates from 9.8 Gb/s
to 12.6 Gb/s (CR4)
80C12B clock recovery for 10 Gb/s rate is supported by the
80A05 module or CR125A clock recovery instrument (Sold
separately)
5
Contact Tektronix for details.
6
The Optical Reference Receiver (ORR) is a 4th-order Bessel-Thomson filter, with a frequency response and tolerances as defined by the standards. Tektronix optimizes the response for best nominal fit and
highest quality mask test results.
7
53.125G PAM4 rate requires the use of the 400G-M4 or 80SJNB software applications and option IMP. Uses DSP and patterns only.
Datasheet
2 www.tek.com